Reordrtn; Multi; Auto; Cngdtct - Canon L100 Service Manual

Hide thumbs Also See for L100:
Table of Contents

Advertisement

● Numeric value parameter
Parameter No.
Function
001;
Not in use
002;
T1 timer
003;
T2 timer
004;
T3 timer
005;
T4 timer
006;
Signal detection table
007;
Signal detection level
008;
Number of signal frequency 0 to 9999

■ REORDRTN

● Bit Switch
Bit No.
Function
Bit 0
Not in use
Bit 1
Signal detection method
FED
Bit 2
Signal frequency
Changed
Bit 3
Not in use
Bit 4
Judgment of intermittent signal start from valid ON signal start from either valid ON
Bit 5
Not in use
Bit 6
Signal form
Continuous
Bit 7
Signal detection
Detected
● Numeric value parameter
Parameter No.
Function
001;
Not in use
002;
T1 timer
003;
T2 timer
004;
T3 timer
005;
T4 timer
006;
Signal detection table
007;
Signal detection level
008;
Number of signal frequency 0 to 9999
8
Service Mode > FAX > Setting of NCU Parameters > CNGDTCT
Setting range
-
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 16
0 to 7
T-8-31
1
0
-
-
FR3
Not changed
-
-
signal or OFF signal
-
-
Intermittent
Not detected
T-8-32
Setting range
-
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 16
0 to 7
T-8-33
8
Service Mode > FAX > Setting of NCU Parameters > CNGDTCT

■ MULTI

● Numeric value parameter
Parameter No.
Function
001;
Not in use
002;
Not in use
003;
Not in use
004;
Not in use
■ AUTO RX
● Numeric value parameter
Parameter No.
Function
001;
CI ON time
0 to 9999 (x 10 msec)
002;
CI LONG ON time
0 to 9999 (x 10 msec)
003;
CI OFF time
0 to 9999 (x 10 msec)
004;
CI LONG OFF time
0 to 9999 (x 10 msec)
005;
CI MAX OFF time
0 to 9999 (x 10 msec)
006;
CI WAIT time
0 to 9999 (x 10 msec)
007;
CI frequency
0 to 9999 (cycle)
008;
CI frequency lower limit 0 to 9999 (Hz)
009;
CI frequency upper limit 0 to 9999 (Hz)

■ CNGDTCT

● Numeric value parameter
Parameter No.
Description
001;
At F/T switching
CNG mIN ON time
002;
CNG mAX ON time
003;
Not in use
004;
Not in use
005;
Not in use
006;
Hit ratio
007;
At direct connecting to
CNG mIN ON time
answering phone
008;
CNG mAX ON time
009;
Tolerable time of
instantaneous interruption
010;
Not in use
011;
Number of detection
012;
Hit ratio
Setting range
-
-
-
-
T-8-34
Setting range
T-8-35
Setting range
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
-
-
-
0 to 9999 (%)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
0 to 9999 (x 10 msec)
-
0 to 9999 (times)
0 to 9999 (%)
T-8-36
8-13
8-13

Hide quick links: