Appliance Break-In; Heat Management; Operation During A Power Outage (Ipi Plus) - Heat & Glo ESCAPE-I35-F Owner's Manual

Care and operation
Hide thumbs Also See for ESCAPE-I35-F:
Table of Contents

Advertisement

F. Appliance Break-In
Initial Break-in Procedure
• The fi replace should be run three to four hours continuously
on high.
• Turn the fi replace off and allow it to completely cool.
• Remove fi xed glass assembly. See Section 4.B.
• Clean fi xed glass assembly. See Section 4.
• Replace the fi xed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the fi replace.
NOTICE! Open windows for air circulation during fi re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
G. Heat Management
Heat Output
Heat Output is managed through the RC300 remote con-
trol that comes standard with the fi replace.
• Turn the appliance on and off.
• Adjust the height of the fl ame by varying the input using
the remote control.
• Adjust the fan speed.
For more information, see the instructions that accompany
the remote control.
H. Operation During A Power Outage (IPI
Plus)
The IntelliFire
Plus intermittent pilot ignition system
TM
comes with a battery backup system that enables the
system to operate in a power outage. The system offers
seamless transition from household AC power to battery
backup. Battery longevity and performance will be affected
by long term exposure to the service temperatures of this
appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency power outage. Batteries should
not be used as a primary long-term power source.
To Operate Fireplace Using Battery Power (DC):
1. Remove the decorative front or door.
2. IPI Battery Tray/Battery Installation:
The removable battery tray is located in the lower left
corner of the appliance next to the lower glass clip. See
Figure 3.3. A notch on the right side of the tray engages
the tray with the appliance. See Figure 3.4. To remove
the tray, rotate the left side of the tray outward and pull to
the left to disengage the notch. Place four AA cell batter-
ies in the tray and return it to the closed position with the
notch engaged in the appliance. Battery polarity must
be correct or module damage will occur.
10
Heat & Glo • Escape-I35-F, Escape-I30-F Owner's Manual • 2347-981 Rev. G • 10/14
Figure 3.3 Battery Tray Located at Bottom Left Side of Appliance
Figure 3.4 Pull Left Side of Tray Out and Disengage Notch
Figure 3.5 Battery Tray Pulled Out
3. Turn the appliance on according to the instructions
below for the appropriate type of control:
Standard Wireless Remote:
Remote receiver is integrated into the ignition module
Use the remote to turn the appliance on.
To preserve battery life, do not use the HI/LO fl ame
or THERMOSTAT options.
Wall Switch or Factory-Installed ON/OFF Switch:
Toggle the switch as you would under normal
circumstances.
Ignition Module:
Locate the ignition module in the control cavity.
Slide the ON/REMOTE/OFF switch to the ON
position.
NOTICE: Some functionality will be lost when using
battery backup including remote control, fan, lights, or
any other auxiliary functions that require household 110-
120 VAC power.
NOTCH