Heat & Glo ESCAPE-I35-F Owner's Manual page 12

Care and operation
Hide thumbs Also See for ESCAPE-I35-F:
Table of Contents

Advertisement

5. Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into lock-out
mode by emitting three audible beeps, then continuously
displaying a RED/GREEN error code at its status
indicator LED.
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section G.
Locate the module reset switch. (See Figure 3.7).
Set the module reset switch to the OFF position.
• Wait fi ve (5) minutes to allow possible accumulated gas
to clear.
Set the module reset switch to ON or REMOTE position.
Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time within a fi ve minute
time period. Gas may accumulate in fi rebox. Call a quali-
fi ed service technician.
Nine Hour Safety Shutdown Feature
The appliance has a safety feature that automatically
shuts down the fi replace after nine hours of continuous
operation without receiving a command from the wall
switch or optional remote.
MODULE RESET SWITCH
Figure 3.7. Module Reset Switch
12
Heat & Glo • Escape-I35-F, Escape-I30-F Owner's Manual • 2347-981 Rev. G • 10/14
Appliance ON/OFF:
The appliance may be turned on and off by the RC300 re-
mote control that comes standard with the fi replace. Con-
sult the instructions and quick reference guide included
with the RC300 for more information.
Fan ON/OFF:
The fan may be turned on and off and the speed adjusted
by the RC300 remote control that comes standard with
the fi replace. Consult the instructions and quick refer-
ence guide included with the RC300 for more information.