135°C.
b. The heater control circuit of IC606 has the built-in function that the software turns off the heater control automatically if the
heater is not turned ON every a fixed time.
c. When the temperature became over 240°C, the heater control circuit of IC606 is turned off forcedly and system reset (IC606
pin 20 becomes Low) will be executed.
The correspondence readings between temperature measured by thermistor and HEX readings
Temperature(°C)
-10
C2
-9
BF
-8
BC
-7
B9
-6
B5
-5
B2
-4
AF
-3
AB
-2
A8
-1
A5
0
A2
1
9E
2
9B
3
98
4
95
5
91
6
8E
7
8B
8
88
9
85
10
82
11
7F
12
7C
13
79
14
76
15
73
16
70
17
6D
18
6A
19
68
20
65
21
63
22
60
HEX reading
Temperature(°C)
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
HEX reading
Temperature(°C)
41
82
40
83
3E
84
3C
85
3A
86
39
87
37
88
36
89
34
90
33
91
31
92
30
93
2F
94
2D
95
2C
96
2B
97
2A
98
29
99
27
100
26
101
25
102
24
103
23
104
22
105
21
106
20
107
20
108
1F
109
1E
110
1D
111
1C
112
1B
113
1B
114
200
HEX reading
12
12
11
11
10
10
10
0F
0F
0E
0E
0E
0D
0D
0D
0C
0C
0C
0C
0B
0B
0B
0A
0A
0A
0A
09
09
09
09
09
08
08

Advertisement

Table of Contents
loading

Table of Contents