Replacing Sas / Sata Backplane; Replacing 2.5- Inch Sas / Sata Backplane; Preliminary Steps - Fujitsu PRIMERGY TX1320 M1 Upgrade And Maintenance Manual

Servers
Hide thumbs Also See for PRIMERGY TX1320 M1:
Table of Contents

Advertisement

Hard disk drives / solid state drives
7.4

Replacing SAS / SATA backplane

Field Replaceable Unit
(FRU)
Preliminary and concluding steps: tool-less
Tools:
Replacing the SAS backplane: Phillips PH2 / (+) No. 2 screw driver
7.4.1

Replacing 2.5- inch SAS / SATA backplane

7.4.1.1

Preliminary steps

I
The 2.5-inch HDD SAS / SATA backplane is mounted on the drive cage.
It is not necessary to remove the drive cage before replacing the
SAS / SATA backplane
Before replacing a 2.5-inch HDD SAS / SATA backplane, perform the following
steps:
Ê Disable BitLocker functionality as described in section
functionality" on page
Ê Shut down the defective server as described in section
server" on page
Ê Disconnect the AC power cord from the system.
Ê Disengage all HDD modules from the server as described in section
"Removing 2.5-inch HDD / SSD modules" on page
I
You need not to remove the 2.5-inch HDD / SSD completely but if you
do so please follow the next caution.
V
CAUTION!
Ensure that all hard disk drives are uniquely identified so that you can
reinsert them into their original bays after replacing the HDD
backplane.
Ê Remove the server cover as described in section
page
55.
140
73.
52.
Upgrade and Maintenance Manual
Hardware: 10 minutes
"Disabling BitLocker
"Shutting down the
122.
"Opening the server" on
TX1320 M1

Hide quick links: