Hard disk drives / solid state drives
For further safety information, please refer to chapter
information" on page
In this chapter
– 2.5-inch HDD / SSD subsystem
"Installing 2.5-inch HDD / SSD modules" on page 118
"Removing 2.5-inch HDD / SSD modules" on page 122
"Replacing a 2.5-inch HDD / SSD module" on page 126
"Replacing SAS / SATA backplane" on page 140
– 3.5-inch HDD subsystem
"Installing 3.5-inch HDD modules" on page 129
"Removing 3.5-inch HDD modules" on page 134
"Replacing a 3.5-inch HDD module" on page 137
7.1

Basic procedure

– Solid state drives (SSDs) are always equipped before installing hard disk
drives.
– Hard disk drives / solid state drives with different capacities are installed
from highest to lowest capacity.
– Hard disk drives with different rotation speeds are installed from highest to
lowest speed.
– When installing hard disk drives with different bus technologies (SAS or
SATA), first install SAS drives and then SATA drives.
– Please refer to sections
mounting sequence.
– Install dummy modules into unused HDD / SSD bays.
I
The mounting order described above is only relevant for the factory
manufacturing process. In case of upgrading a system you need not
consider this mounting sequence.