Safety Instructions
SAFETY INSTRUCTIONS
The operator must read the applicable safety instructions before attempting to operate the equipment.
WARNING
CAUTION
Warning, Caution
Radio Frequency Radiation Hazard
The radar antenna emits electromagnetic radio frequency (RF) energy which can be harmful,
particularly to your eyes. Never look directly into the antenna aperture from a close distance
while the radar ius in operation or eexpose yourself to the transmitting antenna at a close
distance. Distances at which RF radiation level of 100, 50 and 10 W/m are given in the table
below.
Note: If the antenna unit is installed at a close distance in front of the wheel house, your
administration may require halt of transmission within a certain sector of antenna revolution.
This is possible. Ask your FURUNO representive or dealer to provide this feature.
Radar model
FCR-2117/2817
FCR-2127/2827
FCR-2137S/2837S
FCR-2827W
FCR-2837SW
XN12AF: 120cm, XN20AF: 198cm, XN24AF: 243cm, SN30AF: 309cm, SN36AF: 377cm
*1
OR MAF1425B
*2
ii
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided,
can result in minor or moderate injury.
Prohibitive Action
WARNING
Transceiver Magnetron
*2
RTR-078
MG4010
RTR-079
MG5436
RTR-080
MG5223F
RTR-081
MG5436
MG5223F
RTR-082
*1
2
Antenna
100W/m
XN20AF
0.1m
XN24AF
0.1m
0.5m
XN20AF
0.2m
XN24AF
0.1m
SN30AF
0.1m
SN36AF
XN20AF
0.4m
XN24AF
0.2m
-
SN36AF
Mandatory Action
2
2
2
50W/m
10W/m
2.2m
0.7m
1.5m
0.4m
1.7m
4.6m
1.0m
3.3m
2.4m
0.7m
2.0m
1.0m
5.6m
0.5m
3.4m
0.2m
1.9m