CAUTION
service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES.
I
R
NSTALLATION
EQUIREMENTS

Requirements Summary

Weight:...................................................counter must be level and able to support 450 lbs.
Environment:..................................................................................... indoor installation only
Temperature:................................................................... 40 to 100° F ambient temperature
CO
:................................................................................................................. 75 psi at unit
2
Syrup: ....................................................................... 60 psi. min,.70 – .75 ounces per sec.,
...............................not to exceed 3.75 oz/sec Finished Product Flow Rate (.6 gpm) at unit
Water pressure: ....................................................................................60 psi max. at pump
Electrical: ..................................................................................................... see name plate
Water volume........................................................................................................... 125 gph
Product supply beverage tubing ............................................................................ .375 min.
© 2003-2005, IMI Cornelius Inc.

INSTALLATION

— Only trained and certified electrical, plumbing and refrigeration technicians should
IntelliCarb Drop-In Ice Cooled Installation Guide
- 5 -
Publication Number: 630460204INS