IntelliCarb Drop-In Ice Cooled Installation Guide
Adjust Water-To-Syrup Ratio
1.
Remove valve cover and install syrup separator over the diffuser and through the nozzle.
2.
Hold cup under valve and dispense beverage for a specific time (i.e. 2 seconds).
3.
NOTE: Water and syrup must be cold before checking ratios.
4.
Adjust carbonated water flow to the desired rate (such as 90 to 110 ml (3 to 3.75 oz.) per second).
Turn the flow adjuster 1/4 of a turn at a time and recheck the flow.
To increase reading turn clockwise.
5.
Set syrup flow adjuster to get the desired ratio.
6.
Test the valve and adjust until a consistent ratio is delivered three consecutive times.
7.
Repeat procedure for other valves.
Cornelius
Flowmatic
Cornelius
Flowmatic
Cornelius
Flowmatic
Cornelius
Flowmatic
Cornelius
Publication Number: 630460204INS
Water-To-Syrup
ratio cup
Valve Type
Manufacturer
Portion Control
Pushbutton
Lever Type
Autofill Lever
Non-Electric
Maximum Operating
Pressure
130 psi
100 psi
130 psi
100 psi
130 psi
100 psi
130 psi
100 psi
130 psi
- 16 -
Separator
© 2003-2005, IMI Cornelius Inc.