Trouble
VALVE DELIVERS CO
GAS CONTINUOUSLY
VALVE DELIVERS SODA
WATER AND CO
GAS
2
INTERMITTENLY
POOR CARBONATION
© 2003-2005, IMI Cornelius Inc.
TROUBLESHOOTING for Carbonator
Probable Cause
A. Pump motor will not run.
2
B. Pump water supply restricted.
C. Relief valve venting.
D. Worn pump.
A. Pump water supply restricted.
B. Relief valve venting.
C. Inefficient or worn pump.
A. Flooded carbonator.
B. Water temperature too high
(warm).
C. Oil in water supply.
D. Supply water containing too much
air in solution.
E. Poor quality paper cups.
F.
Dirty or greasy glassware.
G. Excessive foam.
H. Flat drinks.
IntelliCarb Drop-In Ice Cooled Installation Guide
A. See PUMP MOTOR WILL NOT
RUN.
B. Clean strainer. Check for faulty
double check valve.
C. Repair or replace.
D. See PUMP MOTOR WILL NOT
STOP .
A. Clean strainer. Check for faulty
single check valve, clogged water
filter, water supply off or blocked,
ruptured tank, faulty liquid level
control or double check valve.
B. Replace or repair.
C. See PUMP MOTOR WILL NOT
STOP .
A. See PUMP MOTOR WILL NOT
RUN.
B. Check water inlet temperature.
Lower temperature provides bet-
ter carbonation.
C. Check pipe thread compound.
Remove and clean and replace
with teflon pipe thread tape.
D. To remove air before it enters
pump, it will be necessary to
install an open tank with float to
control water level.
E. Purchase quality cups made for
this application.
F.
Wash all glassware.
G. CO
contamination within the bever-
age system, poor quality paper
cups or dirty glassware.
H. Draw drinks against side of glass
or cup. Check for insufficient CO
contamination, bad check valve,
ruptured CO
- 31 -
Remedy
BIB pump pressure too high,
2
line
2
Publication Number: 630460204INS