1 Introduction

This manual provides installation and programming information
for the PC1404 four-zone panel security system.

1.1 Compatibility Requirements

The PC1404 product is the central component of the four-zone
security system. Interaction with associated system devices is
Module
PC1404RKZ/PC1404RKZWH
Keypads
PK5500/PK5501/PK5508/PK5516
Keypads
LCD5511 Fixed Message LCD
Keypad
LED5511Z 8-Zone LED Keypad
PC1555RKZ 8-Zone LED Keypad
PTK5507 Touchscreen keypad
PC5200 Power Supply
PC5204 Power Supply with 4
PGMs
PC5208 Low Current PGM Module 20
PC5601 LED Status Module
TL300 T-Link TL300 IP Alarm
Communicator
GS3105/3125-K & BA Wireless
Alarm Communicator
Module
PC5100 2-wire interface
RFK55XX Keypad
RF5132-433 Wireless Receiver
RF5108-433 Wireless Receiver
PC5108 Zone Expander
PC5320 Zone Expander
PC5950 Audio Module
PC5904 Large Audio Station
PC5921 Audio Station
PC5961, PC5962 Small Audio
Station

1.2 Product Specifications

Control and Indicating Equipment Specifications
Features
• Supports zone doubling — supervised and distinguishable
• NC/Single/Double EOL support
• Supports up to 4 keypads
• 1 Partition support
Current Draw, mA
145/150
1.0
125
1.0, 1.1, 1.2, 1.3
85
1.0
100
1.0
85
2.0
200 (standby)
300 (activated)
1.0
400 (Extra Power mode)
20
2.0
20
2.0
1.0
30
1.0
360
1.2-1.5
250 (excluding outputs)
3.0
PC5964 Large Audio Station
PC5401 RS232 Module
PC5400 Printer + DVACS
Escort 5580 Telephone
Interface
TL260 Series
Communicators
GS2060 Series
Wireless Alarm Communicator
TL250 Communicator
TL150 Communicator
IT100 Integration Module
IT120 Integration Module
hardwired, which follows DSC keybus standards. Communica-
tions with the central station may be achieved by a hardwired
phone line. DLS may also be remotely connected to the panel via
phone line or locally connected via the PC-Link header. Shown
below are the supported and unsupported modules for the
PC1404.
Software Versions
4-Wire Smoke Detectors
FSA-410x
FSA-410xT
FSA-410xS
FSA-410xST
FSA-410xLST
FSA-410xR
FSA-410xRT
FSA-410xRS
FSA-410xRST
FSA-410xLRST
Note:
For model numbers above, x = A (ULC); x = B (UL); x = C
(CE)
• 128 events
• Communications: on-board PSTN
• 4 phone numbers
• 2-wire smoke detector support
• 4-wire smoke detector support
• Auto-arming
1 Introduction
2-Wire Smoke Detectors
FSA-210x
FSA-210xT
FSA-210xS
FSA-210xST
FSA-210xLST
FSA-210xR
FSA-210xRT
FSA-210xRS
FSA-210xRST
FSA-210xLRST