Programming Descriptions - DSC PowerSeries PC1404 Installation Manual

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

PC1404

5.3 Programming Descriptions

The following is a description of the programming features and options available in the control panel.
[000] Keypad Function Programming
Function Key
[00] Null
[01]-[02] Not Used
[03] Stay Arm
[04] Away Arm
[05] [*][9] No Entry Arming
[06] [*][4] Door Chime On/Off
[07] Not Used
[08] Zone Bypassing
[09] Trouble Display
[10] Not Used
[11] User Code Programming
[12] User Functions
[13] [*][7][1] Command Output
[14] [*][7][2] Smoke Detector Reset
[15] Not Used
[16] [*][0] Quick Exit
[17] [*][1] Reactivate Stay/Away
Zones
[18] Not Used
[19] [*][7][3] Command Output 3
[20] Night Arming
[21] [*][7][4] Command Output 4
[22]-[24] Not Used
Description
The key is not used and will perform no function when pressed.
Arms the partition to which the keypad is assigned. All stay/away and night type zones will be
automatically bypassed. Delay type zones will provide entry and exit delay. The quick arm
feature controls whether an access code must be entered after pressing this function key. The
exit delay will be silent if the panel is armed using this function key.
Arms the partition to which the keypad is assigned. All stay/away and night type zones will be
active at the end of the exit delay. Delay type zones will provide entry and exit delay. The
quick arm feature controls whether an access code must be entered after pressing this function
key. The exit delay will be audible if the panel is armed using this function key.
After this function key is pressed, the user must enter a valid access code. The partition will
arm and remove entry delay from the partition when the exit delay expires. The key can be
pressed again to enable the entry delay. This function key always requires an access code entry
after it has been pressed.
Pressing the key will toggle the door chime feature on or off. One solid beep means the feature
has been disabled, three short beeps means it has been enabled.
When this function key is pressed, the system enters the [*][1] Zone Bypassing menu. If
desired, the panel can be configured to require an additional access code entry before the sys-
tem enters zone bypassing
When this function key is pressed, the system enters the [*][2] Trouble Display menu.
When this function key is pressed, the keypad prompts for an access code entry. If the master
code or an access code with similar permissions is entered, the system enters the [*][5] User
Code Programming menu.
When this function key is pressed, the keypad prompts for an access code entry. If the master
code or an access code with similar permissions is entered, the system enters the [*][6] User
Functions menu.
This function key provides the user with a simple method of activating a PGM output pro-
grammed as Command Output 1. By default, an access code must be entered after the key is
pressed before the output will activate, but this can be changed by disabling PGM attribute 5.
Pressing this key will cause the panel to deactivate any output programmed as Sensor Reset.
Pressing this key will cause the panel to activate the Quick Exit feature.
This function key provides the user with a simple method of adding stay/away zones into the
system, and it changes the stay armed mode to away armed mode.
This function key provides the user with a simple method of activating PGMs programmed as
Command Output #3. An access code may be required after pressing this key if PGM attribute
5 is enabled.
The system arms with all Night Zones bypassed, even if the delay zones are violated during
exit delay. This key only works while the system is disarmed, or armed in the stay mode. The
panel logs Armed in Night Mode for this closing type. If no night zone types are programmed
on the system, the panel will arm in away mode with an audible exit delay. Normally, no
acknowledgement beeps are sounded and the exit delay is silent if this function key is used to
arm.The quick arming toggle option controls whether an access code must be entered after the
function key is pressed.
This function key provides the user with a simple method of activating a PGM output pro-
grammed as Command Output 4.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents