Se c tion 1: Sy s t e m Int ro du c ti on
1.1
Specifications
Downloading Software Support
•
PC1565 v2.5U uses DLS-3 v1.2 and up.
Flexible Zone Configuration
•
Six fully programmable zones; system expandable to
eight zones using keypad zone inputs and wireless
zones
•
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
•
28 zone types; 8 programmable zone attributes
•
Normally closed, single EOL and double EOL zone wiring
•
Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
•
700mA Supervised Bell Output (current limited at 3
amps), 12VDC
•
Steady or Pulsed Output
EEPROM Memory
•
Does not lose programming or system status on com-
plete AC and Battery failure
Programmable Outputs
•
One programmable voltage output and one programma-
ble voltage output/input; 20 programmable options
•
PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
•
550 mA Auxiliary Supply, 12 VDC
•
Positive Temperature Coefficient (PTC) components
replace fuses
•
Supervision for loss of AC power, low battery
Power Requirements
•
Transformer = 16.0 VAC, 40VA
•
Battery = 12 volt 4 Ah minimum rechargeable sealed
lead acid battery
Remote Keypad Specifications
•
Three keypads available:
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
- LCD5501Z Fixed Message Keypad
•
All keypads have five programmable function keys
•
Connect up to eight keypads
•
4-wire (Quad) connection to Keybus
•
Built in piezoelectric buzzer
Digital Communicator Specifications
•
Supports major communication formats including SIA
and Contact ID
•
Event-initiated personal paging
•
Three programmable telephone numbers
•
Two account numbers
•
Supports GSM1000 cellular communication
•
Supports LINKS2X50 Long Range Radio Transmitter
•
DTMF dialing
•
DPDT line seizure
•
Anti-jam feature
•
Split reporting of selected transmissions to each tele-
phone number
System Supervision Features
The PC1565 continuously monitors a number of possible trou-
ble conditions including:
• AC power failure
• Fault by zone
• Tamper by zone
• Fire trouble
• Failure to communicate
• Low battery by device (wireless)
• Module fault (supervisory or tamper)
False Alarm Prevention Features
• Audible Exit Delay
• Cross Zone Burglary Alarm • Rotating Keypress Buffer
• Communication Delay
Additional Features
•
Auto Arm at specified time
•
Keypad-activated alarm output and communicator test
•
All modules connect to the system via a four wire Keybus
up to 1000'/305m from main panel
•
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad.
•
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
•
Uploading and downloading capability
•
Local downloading capability through the use of the
PC-LINK adaptor
•
Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to
prevent control panel damage
• AUX Power Supply Trouble
• Loss of internal clock
• Bell output trouble
• Telephone line trouble
• Low battery condition (panel)
• Quick Exit
• Urgency on Entry Delay
1