Se c tion 1: Sy s t e m Int ro du c ti on
1.1

Specifications

Downloading Software Support
PC1565 v2.5U uses DLS-3 v1.2 and up.
Flexible Zone Configuration
Six fully programmable zones; system expandable to
eight zones using keypad zone inputs and wireless
zones
38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
28 zone types; 8 programmable zone attributes
Normally closed, single EOL and double EOL zone wiring
Eight wireless zones available using the PC5132 Wireless
Receiver
Audible Alarm Output
700mA Supervised Bell Output (current limited at 3
amps), 12VDC
Steady or Pulsed Output
EEPROM Memory
Does not lose programming or system status on com-
plete AC and Battery failure
Programmable Outputs
One programmable voltage output and one programma-
ble voltage output/input; 20 programmable options
PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
550 mA Auxiliary Supply, 12 VDC
Positive Temperature Coefficient (PTC) components
replace fuses
Supervision for loss of AC power, low battery
Power Requirements
Transformer = 16.0 VAC, 40VA
Battery = 12 volt 4 Ah minimum rechargeable sealed
lead acid battery
Remote Keypad Specifications
Three keypads available:
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
- LCD5501Z Fixed Message Keypad
All keypads have five programmable function keys
Connect up to eight keypads
4-wire (Quad) connection to Keybus
Built in piezoelectric buzzer
Digital Communicator Specifications
Supports major communication formats including SIA
and Contact ID
Event-initiated personal paging
Three programmable telephone numbers
Two account numbers
Supports GSM1000 cellular communication
Supports LINKS2X50 Long Range Radio Transmitter
DTMF dialing
DPDT line seizure
Anti-jam feature
Split reporting of selected transmissions to each tele-
phone number
System Supervision Features
The PC1565 continuously monitors a number of possible trou-
ble conditions including:
• AC power failure
• Fault by zone
• Tamper by zone
• Fire trouble
• Failure to communicate
• Low battery by device (wireless)
• Module fault (supervisory or tamper)
False Alarm Prevention Features
• Audible Exit Delay
• Cross Zone Burglary Alarm • Rotating Keypress Buffer
• Communication Delay
Additional Features
Auto Arm at specified time
Keypad-activated alarm output and communicator test
All modules connect to the system via a four wire Keybus
up to 1000'/305m from main panel
An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad.
Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
Uploading and downloading capability
Local downloading capability through the use of the
PC-LINK adaptor
Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to
prevent control panel damage
• AUX Power Supply Trouble
• Loss of internal clock
• Bell output trouble
• Telephone line trouble
• Low battery condition (panel)
• Quick Exit
• Urgency on Entry Delay