DSC PowerSeries PC1404 Installation Manual page 58

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

PC1404
[381] Second Communicator Options
Option
Description
[1]
ON: Opening After Alarm Keypad Ringback Enabled. When the Opening After Alarm reporting code is successfully
Ringback
transmitted to the monitoring station, the keypad sounds a series of 8 beeps to confirm to the end user that the Opening After
Alarm Code was sent and received. This Ringback occurs for each Opening After Alarm code successfully reported.
OFF: Opening After Alarm Ringback Disabled. When the opening after alarm reporting code is successfully trans-
mitted to the monitoring station, no keypad indications will be provided.
[2]
Future Use
[3]
ON: SIA Uses Programmed Reporting Codes. This option is for use with the SIA communication format. If 00 is
SIA
programmed in the reporting code section, the event will not be communicated. When this option is ON and there is a
Reporting
valid reporting code programmed in the reporting code section, the programmed reporting code will be transmitted. If
Codes
FF is programmed as a reporting code, the event will not be communicated.
Reporting Code Entry
00
FF
01-FE
OFF: SIA Uses Automatic Reporting Codes. When this option is OFF and there is a valid reporting code (01-FE) or
FF programmed in the reporting code section, the panel transmits an automatic reporting code for SIA only. This
would be used when automatic reporting codes are required but there is a requirement for a different reporting code
(like a pulse format).
[4]
ON: Closing Confirmation Enabled. The system beeps the keypad 8 times after successfully transmitting a Closing
Closing
reporting event.
Confirmation
OFF: Closing Confirmation Disabled. The keypad does not beep.
Future Use
[5]-[6]
[7]
ON: Contact ID Uses Programmed Reporting Codes. The Contact ID communications format uses programmed
CID
reporting codes when transmitting to a central station.
Reporting
OFF: Contact ID Uses Automatic Reporting Codes. The Contact ID communications format uses automatic report-
Codes
ing codes as shown in Appendix A when transmitting to central station.
[8]
Future Use
[382] Third Communicator Options
Option
Description
[1]
Future Use
[2]
ON: Alarm Communications Enabled During Walk Test. The system transmits all alarms during Walk Test.
Walk Test
OFF: Alarm Communications Disabled During Walk Test. The system does not report alarm events during
Communications
Walk Test, even if alarms are programmed.
[3]
ON: Communications Cancelled Message Enabled. The Communications Cancelled (LCD) or CC (Icon) mes-
Communications
sage will be displayed if alarms are acknowledged during the transmission delay time + arming cancellation win-
Cancelled Message
dow. This message will be displayed for 5 seconds on all keypads. The acknowledgement can be made with an
access code, disarming function key or a Keyswitch zone.
OFF: Communications Cancelled Message Disabled. The Communications Cancelled LCD message and CC
Icon keypad message will not be created by any method.
[4]
ON: Call Waiting Cancel Enabled. The call waiting dialing string programmed in Section [304] will be dialed
Call Waiting
before the first attempt of each phone number. All subsequent dialing attempts to the same phone number will not
Cancel
use the call waiting cancel string.
OFF: Call Waiting Cancel Disabled. The system does not dial the Call Waiting Cancel string.
Note: A call waiting cancel on a non-call waiting line will prevent successful connection to the central station.
[5]
Future Use
[6]
ON: System AC Failure Transmission Delay in Hours. The System AC Failure Transmission Delay in Section
AC Fail
[377], Option 5 is programmed in hours.
Communications
OFF: System AC Failure Transmission Delay in Minutes. The System AC Failure Transmission Delay in Sec-
Timing
tion [377], Option 5 is programmed in minutes.
Option ON
No Transmission
No Transmission
01-FE Sent
Option OFF
No Transmission
Auto Rep Code Sent
Auto Rep Code Sent