DSC PowerSeries PC1404 Installation Manual page 69

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

Table 1: Reporting Codes
[345]-[346] Bell Circuit Trouble/Rest.
[345]-[346] Fire Trouble/Rest.
2-wire Smoke Trouble/Rest.
[345]-[346] Auxiliary Power Trouble/
Rest.
[346]
TLM Restore
[345]-[346] Gen. System Trouble/Rest. "Service Required" trouble occurs (view troubles using
[345]-[346] Gen. System Supervisory
Trouble/Rest.
[346]
Cold Start
[347]
Phone 1-4 FTC Restore
[347]
Event Buffer is 75% Full
[347]
DLS Lead In
[347]
DLS Lead Out
[347]
Zone Fault/Rest.
[347]
Delinquency
[347]
Installer Lead In
[347]
Installer Lead Out
[348]
Walk Test End
[348]
Walk Test Begin
[348]
Periodic Test
[348]
System Test
*
A/R = alarms/restores; T/R = tampers/restores; O/C = openings/closings; MA/R = miscellaneous alarms/restores;
T = test transmissions
**
UU = user number (user 01-39, 40); ZZ = zone number (01-08).
***
Use the "Fail to close" event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this
code is used.
Table 2: Contact ID Programmed Zone Alarm/Restoral Event Codes
(as per SIA DCS: 'Contact ID' 01-1999): Program any of these codes for zone alarms/
restores when using the standard (non-automatic) Contact ID reporting format.
Medical Alarms
(1)AA Medical
(1)A1 Pendant Transmitter
(1)A2 Fail to Report In
Fire Alarms
(1)1A Fire Alarm
(1)11 Smoke
(1)12 Combustion
(1)13 Water Flow
(1)14 Heat
(1)15 Pull Station
(1)16 Duct
(1)17 Flame
(1)18 Near Alarm
Panic Alarms
(1)2A Panic
(1)21 Duress
(1)22 Silent
(1)23 Audible
Burglar Alarms
(1)3A Burglary
(1)31 Perimeter
(1)32 Interior
(1)33 24 Hour
Software deactivates the bell output if a short is detected
so no additional current is taken from the battery./Bell out-
put restored.
Trouble occurs/restore on a fire zone
Trouble occurs/restore on 2-wire smoke detector zone
Aux voltage supply trouble/restore
Telephone line restored
[*][2])/trouble restored
Control panel has detected an alternate communicator
fault/communications restored.
The PC1404 has restarted after total power loss.
Control panel has restored communications to central
station on Phone 1, 2, 3 or 4 (after FTC)
Event buffer is almost full since last upload
Downloading session start
Downloading session complete
One or more zones have faults/restored
Programmed amount of time (days or hours) for
delinquency has expired without zone activity, or without
system being armed
Installer's mode has been entered
Installer's mode has been exited
End of test
Beginning of test
Periodic system test transmission
[*][6] bell/communications test
(1)34 Entry / Exit
(1)35 Day / Night
(1)36 Outdoor
(1)37 Tamper
(1)38 Near Alarm
General Alarms
(1)4A General Alarm
(1)43 Exp. Module Failure
(1)44 Sensor Tamper
(1)45 Module Tamper
(1)4A Cross Zone Police Code
24 Hour Non-Burglary
(1)5A 24 Hour non-Burg
(1)51 Gas Detected
(1)52 Refrigeration
(1)53 Loss of Heat
(1)54 Water Leakage
(1)55 Foil Break
(1)56 Day Trouble
(1)57 Low Bottled Gas Level
(1)58 High Temp
(1)59 Low Temp
(1)61 Loss of Air Flow
Appendix A: Reporting Code Formats
MA/R
E(3)21-000/ YA-99/YH-99
MA/R
E(3)73-000/
FT-00/FJ-00
R(3)73-000
FT/FJ-99
MA/R
E(3)12-000/
YP-00/YQ-
R(3)12-000
00
MA/R
E(3)51-000 LR-01
MA/R
E(3)AA-000 YX-00/YZ-00
MA/R
E(3)3A-000 ET-00/ER-00
MA/R
R(3)A5-000 RR-00
MA/R
R(3)54-000 YK-00
MA/R
E(6)22-000 JL-00
MA/R
E(4)11-000 RB-00
MA/R
E(4)12-000 RS-00
MA/R
E(3)8A-ZZZ/
UT-ZZ/UJ-ZZ
R(3)8A-ZZZ/
MA/R
E(6)54-
CD-00
000***
MA/R
E(6)27-000 LB-00
MA/R
E(6)28-000 LS-00
T
R(6)A7-UUU
TE-UU
T
TS-UU
E(6)A7-UUU
T
E(6)A2-000 RP-00
T
E(6)A1-000 RX-00