DSC PowerSeries PC1404 Installation Manual page 64

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

PC1404
[903] View Module Supervision
In this mode, the system displays all of the modules presently enrolled on the system as indicated by the corresponding lights below:
Indicator Light
Module
1-8
Keypads 1-8
18
PC5208
19
PC5204
26-29
PC520X 1-4
[990] Installer Lockout Enable
If enabled, the panel gives a distinctive audible indication on power-up (the phone line relay clicks 10 times). This feature has no effect
on a software default (all programming will return to the factory defaults). However, if a hardware default is attempted while Installer
Lockout is enabled, the default does not occur, and the fraudulent attempt is logged to the event buffer.
To enable Installer Lockout perform the following:
1. Enter Installer Programming.
2. Enter Section [990].
3. Enter the Installer Code.
4. Enter Section [990] again.
[991] Installer Lockout Disable
If Installer Lockout is disabled, the panel will restore all programming to factory defaults if a hardware or software default is performed
on the main control panel.
To disable Installer Lockout perform the following:
1. Enter Installer Programming.
2. Enter Section [991].
3. Enter the Installer code.
4. Enter Section [991] again.
Factory Default Main Panel (Hardware)
Perform the following to restore the main control panel to its default settings:
1. Remove AC and battery from panel.
2. Remove all wires from the Zone 1 and PGM1 terminals.
3. With a piece of wire, short the Zone 1 terminal to the PGM1 terminal.
4. Apply AC power to the main panel.
5. When Zone 1 is lit on the keypad (or when Zone 1 shows as open on an LCD keypad) the default is complete.
6. Remove AC Power from the control panel.
7. Reconnect all original wiring and power up the panel.
NOTE: The panel will not default unless AC is used to power the panel.
[999] Restore Panel Factory Defaults
Perform the following to return control panel programming to its factory defaults:
1. Enter Installer Programming.
2. Enter Section [999].
3. Enter the Installer Code.
4. Enter section [999] again.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents