DSC PowerSeries PC1404 Installation Manual page 53

V1.0
Hide thumbs Also See for PowerSeries PC1404:
Table of Contents

Advertisement

[199] Auto-Arming Pre-Alert Timer
In this section, program the time (in minutes) for the Auto-Arming Pre-Alert time. This timer is used for all programmed auto-arming
features (it is not used for no-activity arming). The keypads will provide a steady tone, warning the user that the system is preparing to
arm. The user can enter a valid access code, or valid disarming procedure, to abort the arming sequence. Valid entries are 001 to 255.
[301]-[303], [305] Communication Telephone Numbers
The information in this section applies to Sections [301], [302], [303] and [305].
These sections determine which type of communicator is activated in the event of an alarm condition or other communicated event.
The PC1404 only supports one method of communications, PSTN. GPRS and Ethernet communicators are not supported.
• Entry of [D] followed by a [Telephone Number] terminated with "F" configures the section for telephone dialing.
E.g.: [D12223334444F]
Telephone Communications
All telephone number sections are 32 digits in length. Hexadecimal digits may be programmed in the telephone number to perform
additional functions as follows:
Enter [,][2][,] – HEX B to dial ","
Enter [,][3][,] – HEX C to dial "#"
Enter [,][4][,] – HEX D for an additional dial tone search, as is required for PBX telephone systems
Enter [,][5][,] – HEX E to insert a 2-second pause in the telephone number
i
There is an automatic 2-second pause before additional dial tone searches are initiated.
HEX A is not used.
HEX F represents the end of the phone number (everything after F is ignored).
Pressing [#] in these sections exits and saves the entire phone number.
The panel does not attempt to communicate if no phone number is programmed. This applies to phone numbers 1 to 4.
[304] Call Waiting Cancel String
This is a 6-digit HEX entry that is used to disable the call waiting on a call waiting equipped phone line. This is typically ,70 and is
programmable using Installer Section [304]. Dialing this string before a phone number will disable call waiting for the duration of the
call. If this section is programmed (not FFFFFF), and Section [382] Option 4 is ON, the panel dials this string in place of the first digit
of the phone number. This only applies to the first attempt that is made to each phone number. If 6 digits are not required, terminate
the string with hex Fs to create a 6 digit string.
[310] System Account Number
Program the System Account Number, which will be used by the panel when communicating. Only the SIA format supports 6-digit
account numbers. If a 4-digit account number is required, program the last two digits as data [FF]. If the account code needs to have a 0
in it, and the format is programmed as CID or BPS, a HEX digit A must be used to send a 0.
[320]-[324] Alarm Reporting Codes
These reporting codes are used by the communicator to transmit zone alarms and restores for Zones 1 to 8. These reporting codes are
sent to the Alarm & Restore call direction group
i
Zone alarms transmit to the System Test Transmission Call Direction when they are being transmitted as part of the walk
test (enabled if Section [382] Option [2] is ON).
[328] Miscellaneous Alarm Reporting Codes
Duress Alarm
This reporting code is transmitted whenever a Duress code is used to perform any function on the system. The reporting code is sent to
the Alarm & Restore call direction group.
Opening After Alarm
This reporting code is transmitted when the system is disarmed after an alarm; if an alarm occurred during the previous armed period.
The reporting code is sent to the Alarm & Restore call direction group.
Recent Closing
This reporting code is transmitted when an alarm occurs within two minutes of system arming.
Zone Expander Supervisory Alarm/Restore
This reporting code is generated when a keypad with a keypad zone enrolled is no longer responding to the panel on keybus. The report-
ing code is sent to the Alarm & Restore call direction group.
Police Code Alarm
Two zones on the same partition go into alarm during any given armed-to-armed period (including 24-Hr. zones).
[329] Priority Alarm and Restore Reporting Codes (Fire, Auxiliary, and Panic Alarms/Restores)
If enabled and used to generate manual alarms, these reporting codes are sent to the Alarm & Restore Call Direction group.
.
5.3 Programming Descriptions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents