5.2 Programming Worksheets

Keypad Partition/Slot and Function Key Programming
[000] Function Key Programming
Note: Keypad enrollment must be done at each keypad requiring programming. Function keys are programmable in each individual
keypad. The keypad being programmed must be used to access Installer Programming, followed by Section [000] and digits 1-5 for
function keys 1 to 5.
[0] Slot address
[1] Function Key 1 Assignment
[2] Function Key 2 Assignment
[3] Function Key 3 Assignment
[4] Function Key 4 Assignment
[5] Function Key 5 Assignment
Function Key Options:
00 Null Key
01 Future Use
02 Future Use
03 Stay Arm
04 Away Arm
05 [,][9] No Entry Arm
06 [,][4] Chime On / Off
07 Future Use
08 [,][1] Bypass Mode
*
This function key must not be used in CP-01 listed systems.
Keypad Defaults

[001] Zone Definitions

00 Null Zone (Not Used)
01 Delay 1*
02 Delay 2*
03 Instant*
04 Interior*
05 Interior, Stay/Away*
06 Delay, Stay/Away*
07 Delayed 24 Hr. Fire
08 Standard 24 Hr. Fire
09 24 Hour Supervisory
10 24 Hour Supervisory Buzzer*
11 24 Hour Burglary*
12 Not Used
13 24 Hour Gas*
*For burglary applications only
[001] Zone 1–8 Definitions
Zone
Default
01
01
I _ ____I _ ____I
02
03
I _ ____I _ ____I
03
03
I _ ____I _ ____I
04
03
I _ ____I _ ____I
Note: If zone doubling is enabled, keypad zones will not work.
Note: If zone doubling is enabled, fire zones cannot be used with zone terminals 1 to 8. Two-
wire smoke detectors can still be used.
16
For the partition, 0-8; for the slot, 1-8. For example, to enroll a keypad on the main partition and slot
Valid entries are 00-25
Valid entries are 00-25
Valid entries are 00-25
Valid entries are 00-25
Valid entries are 00-25
09 Future Use
10 Future Use
11 Future Use
12 Future Use
13 [,][7][1] Command Output #1
14 [,][7][2] Command Output #2/Sensor Reset
15 Future Use
16 [,][0] Quick Exit
17 [,][1] Reactivate Stay/Away Zones
Key 1
Key 2
14 24 Hour Heat*
15 24 Hour Medical*
16 24 Hour Panic*
17 24 Hour Emergency*
18 Not Used
19 24 Hour Water*
20 24 Hour Freeze*
21 24 Hour Latching Tamper
22 Momentary Keyswitch Arm*
23 Maintained Keyswitch Arm *
24 Not Used
25 Interior Delay*
26 24-hour Non-Alarm (Local Alarm)
27 Not Used
Zone
05 (ZD or keypad zone only)
06 (ZD or keypad zone only)
07 (ZD or keypad zone only)
08 (ZD or keypad zone only)
6, enter 16.
18 Future Use
19 [,][7][3] Command Output #3
20 Night Arm
21 [,][7][4] Command Output #4
22 Future Use
23 Future Use
24 Future Use
25 Instant Stay Arm
26-33 Future Use
Key 3
Key 4
28 Not Used
29 Not Used
30 Not Used
31 Day Zone
32 Instant Stay/Away*
33 Not Used
34 Not Used
35 24 Hour Bell
36 24 Hr. Non-Latching Tamper
37 Night Zone*
41 24-Hour CO Detection
Default
04
I _ ____I _ ____I
04
I _ ____I _ ____I
04
I _ ____I _ ____I
04
I _ ____I _ ____I
*
Key 5