Parallel Strobe
This setting lets the user adjust the factory setting for the amount of
time strobe is sampled to determine that valid data is available on
the parallel port. Each increment of the strobe adjust value means
the strobe is sampled 50ns longer.
Perform the following steps to change the Parallel Strobe Adjust:
1. Enter the configuration mode. See
page 3-14
2. Perform a double click button press seven times. This moves to
the Parallel Strobe item on the configuration menu. The Parallel
Strobe (Load Paper) LED is blinking.
3. The current Parallel Strobe setting is indicated by the
Off/On/Auto (Press Button) LED. When the LED is off, the
Parallel Strobe is set to normal. When the LED is on, the
Parallel Strobe is set to +1. When the LED is blinking, the
Parallel Strobe is set to +2. Perform a brief button press to
select the Parallel Strobe setting.
4. Perform a long button press. All LEDs blink once, indicating the
setting is saved.
5. Exit the configuration mode by turning the printer power off.
Off/On/Auto
for more information.
Setting Value
Parallel strobe adjust is set to normal.
Parallel strobe adjust is set to +1.
Parallel strobe adjust is set to +2.