e-STUDIO 16P
ROM Checksum Failure Service Error Code
ksum Failure Service Error Code
The operator panel button has been pushed and a ROM checksum
failure service error has occurred.
Once the error code is displayed, if the operator panel button is
pushed again, the operator panel displays the service error
indication – all 6 indicator LEDs blinking. Continual pressing of the
operator panel button causes the LEDs to repeat in the following
order:
1. Service error indication
2. ROM checksum failure service error code indication
3. Service error indication
Replace the ROM SIMM. If this does not correct the problem,
replace the controller board.