Figure I-3. Simm Location - Bay Networks 281xSA Using Manual

Ethernet hub
Table of Contents

Advertisement

Replacing SIMMs
I-6
Total memory varies and depends on the type of SIMM installed.
To replace the SIMM, follow these steps:
1.
Locate the SIMM socket at location U21 on the circuit board.
Locate socket U21 (see Figure I-3). Socket U21 is a "tilt-down" SIMM
socket—you insert the SIMM into the empty socket vertically and then tilt
the SIMM back until it snaps into the socket.
Front
of hub

Figure I-3. SIMM location

CAUTION: If you do not wear a discharge leash to free yourself of static
before touching the circuit board or the SIMM, free yourself of static by
touching the metal of the chassis before handling the NMM and the SIMM.
2.
Remove the SIMM that is already installed in the socket
(see Figure I-4).
JP1
JP2
SIMM
socket
4859
893-743-A