Message
Error identifying slot numbers for the
specified board names.
Cannot unbind specified slot from
AFT group. Make sure that the slot
you specified is for the primary
adapter in an AFT group.
LAN adapter at slot nnnn (Port 0xaa)
failed to reset. Check the state of the
adapter.
AFT is not supported on this version
of NetWare.
Failed to allocate resources tags.
Please unload all LAN drivers before
unloading AFT.NLM.
NDIS 4.0 (Windows NT
This section explains the error messages for the NDIS drivers. The explanation and
recommended action are included with each message.
Note: Although the term "adapter" is used in these messages, the messages might
Error code (hex)
Description
0x00
Explanation: The driver could not register the specified interrupt.
Action: Using the Configuration/Setup Utility program, make sure that a PCI interrupt is assigned
to the Ethernet card, and that Ethernet is enabled.
0x01
Explanation: One of the PCI/PCI-X cards did not get the required resources.
Action: Using the Configuration/Setup Utility program, make sure that a PCI interrupt is assigned
to the Ethernet card, and that Ethernet is enabled.
0x02
Explanation: Bad node address (multicast address).
Action: Make sure the locally administered address is valid, if one is specified. The address
cannot be a multicast address.
Description
Explanation: The mapping between the board name entered and the slot
number for an adapter could not be established.
Action: Check the board name for the adapter before issuing the bind
command. If the problem remains, contact the network supplier.
Explanation: The number entered in the unbind command was not the
primary adapter in an AFT group.
Action: Reissue the unbind command and specify the slot number for the
primary adapter.
Explanation: The adapter that you specified could not be initialized.
Action:
1. Load the driver for the supported adapter.
2. Check that the adapter is seated properly in the slot and try loading the
AFT module again.
If the problem remains, contact the network supplier.
Explanation: The NetWare on the computer is not a version supported by
AFT.
Action: Load and bind AFT only on supported versions of NetWare (currently
version 5.1 and above).
Explanation: An unknown error has occurred when trying to allocate needed
resources for the AFT module.
Action: Check system configuration. If the problem remains, contact the
network supplier.
Explanation: An attempt was made to unload the AFT.NLM module before
unloading the adapter driver.
Action: Unload the adapter driver before unloading the AFT module.
®
also apply to the integrated Ethernet controller on the system board.