Error code/symptom
4xxx thru 5xxx (Code DRAM error)
6xxx (Cache DRAM error) (ServeRAID-4H only)
7xxx thru 8xxx (Host/local PCI bus interface error)
9003
9xxx thru BZxx (SCSI bus error caused by cables,
termination, defective drives, etc.). Z refers to the specific
channel or channels that cause the error.
EFFE (Firmware code corrupt or download jumpers are in
place)
FFFF or other code not listed
112
IBM IntelliStation E Pro Types 6216 and 6226: Hardware Maintenance Manual
FRU/action
1. Install download jumpers, flash latest level BIOS code
and firmware for controller; then, remove jumpers.
2. ServeRAID controller.
1. Reseat adapter.
2. Install download jumpers, flash latest level BIOS code
and firmware for controller; then, remove jumpers.
3. ServeRAID controller.
1. Flash latest level of BIOS code and firmware for
controller.
2. If ServeRAID-4x controller, replace controller.
3. If ServeRAID-5i controller, integrated RAID controller
on the server.
1. Flash latest level of BIOS code and firmware for
controller.
2. Confirm that this controller is a supported option for
this system.
3. ServeRAID controller.
4. Integrated RAID controller on the server).
1. Follow indications at "POST (ISPR) error procedures"
on page 109. Follow those instructions before
continuing with the next steps listed in this index.
2. Hard disk drive cable.
3. Hard disk drive backplane.
4. Hard disk drive.
5. ServeRAID controller.
1. Flash latest level BIOS code and firmware for
controller; then, remove jumpers.
2. ServeRAID controller.
1. Follow indications at "POST (ISPR) error procedures"
on page 109.
2. Hard disk drive cable.
3. Hard disk drive backplane.
4. Hard disk drive.
5. ServeRAID controller.