IBM IntelliStation E Pro Hardware Maintenance Manual page 118

Types 6216 and 6226
Hide thumbs Also See for IntelliStation E Pro:
Table of Contents

Advertisement

Error code/symptom
962 (Parallel port error)
11XX (System board serial port 1 or 2
error)
1762 (Hard drive configuration error, IDE
only.)
178X (Hard drive error, IDE only.)
1800 (No more hardware interrupt
available for PCI adapter.)
1801 (No more ROM space available for
PIC adapter.)
1962 (Drive does not contain a valid boot
sector)
5962 (IDE CD-ROM drive configuration
error)
8603 (Pointing-device error)
00012000 (Machine check architecture
error.)
00019701 (Microprocessor 1 failed)
00180200 (No more I/O space available
for PCI adapter.)
00180300 (No more memory above 1MB
for PCI adapter.)
108
IBM IntelliStation E Pro Types 6216 and 6226: Hardware Maintenance Manual
FRU/action
1. Run the Configuration/Setup Utility program.
2. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Hard disk drive.
2. Hard disk cables.
3. Run the Configuration/Setup Utility program.
4. System board.
1. Hard disk cables
2. Hard disk adapter
3. Hard disk drive
4. System board
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
1. Run the Configuration/Setup Utility program.
2. Remove adapter.
3. Disable the adapter BIOs and run the Configuration/Setup Utility
program.
1. Verify that a startable operating system is installed.
2. Run diagnostics.
3. Hard disk drive.
4. SCSI backplane.
5. Cable.
6. System board.
1. Run the Configuration/Setup Utility program.
2. CD-ROM drive.
3. CD-ROM power cable.
4. IDE cable.
5. System board.
6. Battery.
1. Pointing device
2. System board
1. Microprocessor
2. System board
1. Microprocessor
2. System board
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.

Advertisement