IBM IntelliStation E Pro Hardware Maintenance Manual page 108

Types 6216 and 6226
Hide thumbs Also See for IntelliStation E Pro:
Table of Contents

Advertisement

Error code/symptom
015-XXX-001 (USB interface not found,
board damaged)
015-XXX-198 (USB device connected
during USB test.)
020-XXX-000 (Failed PCI interface test.)
030-XXX-00N (Failed SCSI interface test.)
035-XXX-099 (No adapters were found.)
035-XXX-S99 (Failed RAID test on PCI slot
S. S = number of failing PCI slot.)
035-XXX-SNN (s = number of failing PCI
slot, nn = SCSI ID of failing fixed disk.)
035-253-S99 (RAID adapter initialization
failure.)
089-XXX-001 (Failed microprocessor test.)
089-XXX-002 (Failed optional
microprocessor test.)
201-XXX-0NN (Failed memory test.)
201-XXX-999 (Multiple DIMM failure, see
error text.)
202-XXX-001 (Failed system cache test.)
202-XXX-002 (Failed system cache test.)
206-XXX-000 (Failed diskette drive test.)
98
IBM IntelliStation E Pro Types 6216 and 6226: Hardware Maintenance Manual
FRU/action
1. System board
1. Remove USB devices from USB1, USB2, USB3 and USB4; then,
run the USB interface test again.
2. System board.
v System board
v If N=0, system board; if N>0, SCSI adapter in slot N.
v If adapter is installed re-check connection.
1. RAID adapter
2. Cable
3. System board
v Hard disk drive with SCSI ID nn on RAID adapter in PCI slot s
1. ServeRAID
adapter in slot s is not configured properly. Obtain
the basic and extended configuration status and see the ServeRAID
Hardware Maintenance Manual for more information.
2. Cable.
3. Adapter.
1. Verify microprocessor 1 is installed an seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 1.
4. System board.
1. Verify microprocessor 2 is installed an seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 2.
4. System board.
1. DIMM Location slots 1-2 where nn = DIMM location
Note: nn 1=DIMM 1; 2=DIMM 2
2. System board
1. See error text for failing DIMMs.
2. System board.
1. Verify microprocessor 1 is installed an seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 1.
4. System board.
1. Verify microprocessor 2 is installed an seated correctly.
2. Verify BIOS code is at latest level.
3. Microprocessor 2.
4. System board.
1. Try test with another diskette.
2. Cable.
3. Diskette drive.
4. System board.

Advertisement

Table of Contents
loading

Table of Contents