Section Viii: Troubleshooting - New Buck Corporation 74 Manual

Non-catalytic unit
Hide thumbs Also See for 74:
Table of Contents

Advertisement

PROBLEM
1. Sluggish Heater
SECTION VIII
TROUBLESHOOTING
POSSIBLE CAUSE
1. Obstruction in Chimney
2. Improperly sealed trim
kit or direct connect kit
3. Manual damper in
chimney is closed
4. Wet or unseasoned wood
being burned
5. Poor chimney draft
6. Improper wood loading
Page 32
SOLUTION
1. Check for and remove
obstruction
2. (a) Check trim kit
gasketing seal to
fireplace and gasket as
necessary to seal unit.
Gasket under front
bottom of stove if
needed. (b) Check seal
if using direct connect
and correct.
3. Open manual damper
and wire shut with
stainless steel wire or
remove damper
4. Burn dry natural
seasoned hard wood
5. Improper chimney height
or wrong size flue is
being used. Cooler
temperatures caused by
external chimney.
6. Load wood length way
from front to rear

Advertisement