SECTION II

MOBILE HOME INSTALLATIONS

Listed NEW BUCK CORPORATION:
Model
51ZC
Zero Clearance Cabinet Assembly For Use With Models 51,T51,74, and 74 Only.
CAUTION:
Read through all of these instructions carefully. Follow approved Chimney Manufac-
turer's Installation exactly. Failure to install the Cabinet Fireplace, Stove and Chimney as described in
the instructions will void the manufacturer's warranty and may have an effect on your Homeowner's
Insurance. A major cause of chimney related fires is failure to maintain required clearances (air spaces)
to combustible materials. It is of the utmost importance that these parts be installed only in accordance
with these instructions.
"DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE."
"DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS."
The Zero-Clearance Cabinet and the with either Models 51, T-51, 74 models, and T-74 (here after re-
ferred to as the 51ZC) is designed for installation in a family dwelling, where minimum clearance is
desired.
INSTALLATION PRECAUTIONS
The following precautions are mandatory for a safe installation.
(A) Compliance with local building codes and regulations is mandatory.
(B) Be careful not to damage the unit in handling and unpacking component parts and accessories.
(C) Any 6" chimney systems that bear the UL 103 HT Label are approved for use the model ZC51.
(D) The chimney must extend a minimum of three feet (3') above the highest point where it penetrates
the roof (three feet (3') above a flat roof or up to a 2 /12 pitch roof ), and the chimney must extend a
minimum of two feet (2') higher than any portion of the building within ten feet (10') of the chim-
ney. The minimum height is fourteen feet (14'). The maximum height is thirty feet (30'). A two-inch
(2") clearance must be maintained between the chimney and any combustible materials at all points.
(E) A rain cap must be used to terminate the chimney to prevent down-draft. Use the factory approved
rain cap which is approved for the type chimney being installed.
(F) "DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE." DO NOT USE A FLUE INTENDED FOR A GAS APPLIANCE."DO
NOT CONNECT TO ANY DISTRIBUTION DUCT OR SYSTEM."
(G) Do not build a fire directly inside the ZC Cabinet. It is designed solely for housing the Models 51,
T-51, 74, and T-74 stoves.
"WARNING"
(H)
( I ) The structural integrity of the mobile home floor, wall, and ceiling/roof must be maintained.
Do not install in a sleeping room.