Message
Diskette drive B error
Incorrect Drive B type - run SETUP
System cache Error - Cache disabled
Verify CPU Frequency selection in Setup
CPU runtime error (IERR#) detected
Uncorrectable memory error
Memory configuration has changed - Run
SETUP
No usable system memory
Memory module disabled! This module is no
longer available for the operating system.
No usable CPU
Patch for installed CPU not loaded. Please run
the bios flash update diskette.
table: List of POST Errors
The settings error or the baseboard error. Power off the server
and turn it back on. If the message still appears, the baseboard
must be replaced. Contact an office listed in the "Contact Infor-
mation" of "Start Guide".
System cache error. Power off the server and turn it back on. If
the message still appears, check the error log and replace the
CPU if it is faulty. Else, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
CPU error. Power off the server and turn it back on. If the
message still appears, check the error log and replace the CPU
if it is faulty. If the message still appears, the baseboard must
be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Installed CPU error. Check the error log and replace the CPU.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Memory error. Check the error log and replace the memory
module. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
DRAM error. The DRAM size has changed since the last
startup. Check the error log and replace the memory module. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
Memory error. No memory modules available to the system are
detected. Check the error log and replace the memory module.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide". After the replacement, enable the use of the memory in
the BIOS Setup Utility.
Memory error. Turn off the server and check whether the
memory module is installed correctly. If the message still
appears, check the error log and replace the memory module. If
the message still appears after the replacement, the baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
Installed CPU error. Replace the CPU. If the message still
appears, the baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide". After the
replacement, enable the CPU in the BIOS Setup Utility.
Check that the correct CPU is installed. If the correct CPU is
installed and the message is displayed, select [Yes] for the
[Reset Configuration Data] setting on the [Advanced] menu of
the BIOS Setup Utility. If the message still appears, the CPU or
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
PRIMERGY TX120 User's Guide
Description
9