Dc Power; Environment; Table 25: G10 Cmts Environmental Specifications - Juniper G10 CMTS Hardware Manual

Juniper networks, inc. g10 cmts hardware guide
Hide thumbs Also See for G10 CMTS:
Table of Contents

Advertisement

Environment

DC Power

Environment

Table 25: G10 CMTS Environmental Specifications

72
JUNOSg 3.0 G10 CMTS Hardware Guide
The G10 CMTS requires a DC power source that operates within a voltage range of –36 to
–75 VDC. Unlike the AC configuration, the DC power transition modules do not operate
independently. Each DC power transition module supports the power supplies in both
domains of the chassis. If one DC power transition module fails, all the current for the system
must be supplied from a single power source. Therefore, within the United States, a 50 A
circuit breaker (36 A maximum, plus margin) must be used with each of the two independent
DC power sources connected to the CMTS. Outside the United States, each DC power source
must have circuit breaker protection to account for a maximum current of 36 A, plus
additional margin required by local regulations.
Use the factory-supplied DC power cord ring lugs, and wire according to your local code for
the DC power cord connection to the G10 CMTS.
The installation site must meet the specifications provided in Table 25 to maintain the proper
environmental conditions for the G10 CMTS.
Parameter
Condition
Temperature
Ambient operating
Ambient non-operating
Humidity
Ambient operating and non-operating
Altitude
Operating and non-operating
Vibration
Operating
Non-operating
Requirement
0° to +40°C (0° to +104°F)
–35° to +60°C (–31° to +140°F)
10% to 90% (non-condensing)
0 to 3048 m (10,000 ft)
5 Hz to 200 Hz, at 1.0g (1.0 oct/min)
5 Hz to 200 Hz, at 1.0g (1.0 oct/min)
200 Hz to 500 Hz, at 2.0g (1.0 oct/min)