Remove An Hfc Connector Module Or Sim - Juniper G10 CMTS Hardware Manual

Juniper networks, inc. g10 cmts hardware guide
Hide thumbs Also See for G10 CMTS:
Table of Contents

Advertisement

Module Removal

Remove an HFC Connector Module or SIM

168
JUNOSg 3.0 G10 CMTS Hardware Guide
The HFC Connector Module and the SIM are hot-swappable, so you can remove them or
install them while the CMTS is powered on.
1.
Disconnect all cables that are attached to the module ports. If appropriate, tag each cable
with its corresponding module port.
2.
Loosen the two retainer screws.
3.
Press upward and downward on the ejector releases (action #1 in Figure 48 on
page 169).
4.
Simultaneously pull the ejectors away from the module faceplate. The ejectors should
rest at approximately 45° from their locked position. At this point, the module is
physically and electrically removed from its connectors on the midplane.
5.
Slowly slide the module out of its slot until it is fully removed from the system.
6.
Insert the module into an anti-static bag, being careful to avoid directly touching any
component on the module. We recommend that you handle the module by its card
edges or ejectors.
7.
If the module will not be replaced, you must install an air management panel in its
place. Tighten the two retainer screws on the air management panel by applying 3 in-lb
of torque to each screw.

Advertisement

Table of Contents
loading

Table of Contents