8. Replace the remaining firebox components.
9. Replace the glass.
10. Remove and discard the screws (see "a" below) holding the stock regulator in place (see "b" below).
Remove the stock regulator and gasket (see "c" below). Place the LP regulator in place, making
sure the pre-fitted gasket (see "c" below) is in place.
NOTE: There is a label on the base of the regulator knob indicating regulator type (NG or LP).
Secure the regulator with the screws included with the regulator – tighten to 25 lb-in of torque
(2.82 NM). Place the included label on the valve body where it can be easily seen to insure
proper identification.
NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is
lit.
11. Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve.