Facing Requirements - Travis Industries 4415 HO GSR2 Installation Manual

Travis industries fireplace
Hide thumbs Also See for 4415 HO GSR2:
Table of Contents

Advertisement

Facing Requirements

The included fiber board is required and must remain attached to the fireplace (see "a" below).
Drywall (or other combustible) may be placed above the fiber board (see "b" below) and to the sides and
below the face of the fireplace.
Tile or other non-combustible facing may be placed along the front of the fireplace around the perimeter of the
glass opening (see "c" below). Typical installations use 12" (305mm) or greater of non-combustible facing
around the perimeter of the glass opening. Do not install facing over the ledge to the glass opening.
Do not use Liquid Nails ® or low-temperature adhesive to attach tile or other non-combustible to the front of
the fireplace. These adhesives are not designed for high-temperature applications and may release an odor
after installation.
© Travis Industries
Installation
(for qualified installers only)
b
c
45-1/4"
1150mm
a
4140108
29
(a) Fiber Board
(included with
fireplace)
(b) Drywall (or other
11-1/4"
combustible)
286mm
(c) Tile (or other
non-
combustible)
15-3/4"
401mm
10-3/8"
264mm
100-01353

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shield 60156015 ho gsr2

Table of Contents