Facing Requirements
•
The included fiber board is required and must remain attached to the fireplace (see "a" below).
•
Drywall (or other combustible) may be placed above the fiber board (see "b" below) and to the sides and
below the face of the fireplace.
•
Tile or other non-combustible facing may be placed along the front of the fireplace around the perimeter of the
glass opening (see "c" below). Typical installations use 12" (305mm) or greater of non-combustible facing
around the perimeter of the glass opening. Do not install facing over the ledge to the glass opening.
•
Do not use Liquid Nails ® or low-temperature adhesive to attach tile or other non-combustible to the front of
the fireplace. These adhesives are not designed for high-temperature applications and may release an odor
after installation.
© Travis Industries
Installation
(for qualified installers only)
b
c
45-1/4"
1150mm
a
4140108
29
(a) Fiber Board
(included with
fireplace)
(b) Drywall (or other
11-1/4"
combustible)
286mm
(c) Tile (or other
non-
combustible)
15-3/4"
401mm
10-3/8"
264mm
100-01353