Vent Configuration: Horizontal Termination with Vertical Rise – 8" Vent
• Use 5x8" Diameter Coaxial Vent
• NOTE: Use the included firestop (s). The included heat shield may be discarded.
• The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
• Up to 3 elbows (45° or 90°) may be used. Only one horizontal elbow may be used.
• HINT: Use minimum vent kit "H" (96200332) from Travis Industries (additional vent may be
required).
20 feet (6m) max
Intake Restrictor # 1 (stock)
Exhaust Restrictor # 2
Diffuser Closed (stock)
15 feet (4.5m)
Intake Restrictor # 1 (stock)
10 feet (3m)
Exhaust Restrictor # 4
Diffuser Closed (stock)
5 feet (1.5m)
Minimum 2' Rise
0 feet
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
© Travis Industries
Installation
(for qualified installers only)
H2
H1
Intake Restrictor # 1 (stock)
Exhaust Restrictor # 4
Diffuser Closed (stock)
Intake Restrictor # 1 (stock)
Exhaust Restrictor # 1 for NG (stock)
Exhaust Restrictor # 0 for LP (removed)
Diffuser Closed (stock)
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
This is considered a
vertical elbow
4140108
20 feet (6m) max
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
100-01353