6.2.3 CONNECTOR SIGNALS

These connectors are found on both the previous and cost improvement board versions with the
exception of connector J33 which is not on the previous version.
(PARALLEL INTERFACE)
STROB
DACX(0)
DACX(1)
DACX(2)
DACX(3)
DACX(4)
DACX(5)
DACX(6)
DACX(7)
ACK00 10 29 GND
BUSY1 11 30 GND
PAPEMP 12 31 IMPRA
SELOUT 13 32 FAULTCX
AUTOLF 14 33 GND
- 15 34 -
GND 16 35 TIR00
GND 17 36 SELINP
VCC 18 37 GND
(TRANSPORT MOTOR)
(POWER SUPPLY)
683311W
J33
19 GND
1 20 GND
2 21 GND
3 22 GND
4 23 GND
5 24 GND
6 25 GND
7 26 GND
8 27 GND
9 28 GND
38 GND
J77
1
FASEA
2
FASEB
3
FASEC
4
FASED
J82
1
PIU35
2
GND
J34
(RS232 INTERFACE)
GND
1
14
TXD1
2
15
RXD1
3
16
RTS1
4
17
CTS1
5
18
DSR1
6
19
GND
7
20
DTR
DCD1
8
21
GND
9
22
10
23
11
24
12
25
13
J85
(PRINT NEEDLE CONNECTION)
1
TESTE
2
LEBCA
3
FOBCA
4
VCC
5
R0224
6
SPL(2)
7
R0422
8
SPL(4)
9
R0620
10
SPL(6)
11
R1214
12
SPL(12)
13
R0717
14
SPL(17)
15
R1113
16
SPL(13)
17
R1113
18
SPL(11)
19
R0519
20
SPL(5)
21
R0422
22
SPL(22)
23
R0123
24
SPL(23)
25
R0519
26
SPL(19)
Service Manual
J49
(CONSOLE)
1
GND
2
P5CONS
3
LED3
4
LEDLOC
5
LED2
6
LED1
7
LEDON
8
TAS01
9
TALOC
10
TAS02
11
COPEN
12
GND
J86
(PRINT NEEDLE CONNECTION)
1
R0818
2
SPL(8)
3
R1016
4
SPL(10)
5
R1214
6
SPL(14)
7
R0818
8
SPL(18)
9
R1016
10
SPL(16)
11
R0915
12
SPL(15)
13
R0915
14
SPL(9)
15
R0717
16
SPL(7)
17
R0321
18
SPL(3)
19
R0123
20
SPL(1)
21
R0620
22
SPL(20)
23
R0224
24
SPL(24)
25
R0321
26
SPL(21)
6-5