Replacing The 15.0-Inch Xga Lg Philips Fluorescent Lamp - Toshiba TECRA S4 Maintenance Manual

Personal computer
Hide thumbs Also See for TECRA S4:
Table of Contents

Advertisement

4 Replacement Procedure

4.30.1 Replacing the 15.0-inch XGA LG Philips Fluorescent Lamp

CAUTION: When replacing the fluorescent lamp, wear finger covers or gloves to avoid
contaminating or damaging the LCD panel. Be careful not to let dust or
other foreign substance into the module.
Disassembling the 15.0-inch XGA LG Philips Fluorescent Lamp
To disassemble the 15.0-inch XGA LG Philips fluorescent lamp, follow the steps below and
refer to Figure 4-57 to 4-64.
Disassembly of outside tape / Cover shield
1. Disassembly of Cover shield (S).
CAUTION: Pressure or stress should not be given on Source PCB.
Usage of gloves with anti-electric discharge coating is recommended.
To eliminate possible damage on circuits occurred by ESC.
2. Disassembly of Cover shield (G).
CAUTION: Pressure or stress should not be given on Gate COF.
3. Disassembly of Tape Adhesive used for Top case fixing.
Disassembly of Tape Adhesive used for B/L Wire fixing.
CAUTION: Pressure or stress should not be given on Top case during this process.
4-76
[CONFIDENTIAL]
4.30 Fluorescent Lamp
TECRA S3 Maintenance Manual (960-532)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tecra s3

Table of Contents