IBM 4247 Maintenance Information page 188

Table of Contents

Advertisement

Threshold values written in NVRAM display:
where:
v x1 is the threshold for manual path
v x2 is the threshold for front path
v x3 is the threshold for rear path and rollers closed
v x4 is the threshold for rear path and rollers open
v x1, x2, x3, x4 are numbers in hexadecimal format corresponding to the threshold voltages with resolution
of 20 mV.
Press the Micro
7. The following displays:
This part of the test is intended for use by Product Engineering. It allows the user to examine sensor output
voltages.
8. Press the Load/Form Feed key to skip to step 9.
Press the Micro
The current sensor measurements display:
where:
v x1 is manual path measurement
v x2 is front path measurement
v x3 is rear path measurement
key to go to step 7.
key to enter.
Cx1 Fx2 Rx3(x4)
Y SENSOR LEVEL N
C:x1 F:x2 R:x3
188
Chapter 2. Diagnostics