Panasonic BB-HCM331A Installation/Troubleshooting Manual page 58

Network camera
Table of Contents

Advertisement

Installation/Troubleshooting
Problem
E-mail or FTP
transfer cannot
be sent in
transport mode.
58
• The network settings are not set correctly.
Cancel the IPsec settings on the server, PC and camera, and
check that the camera images can be transferred. If they can
be transferred, the IPsec settings were not set correctly. Set
them correctly (see page 51 of Operating Instructions on the
Setup CD-ROM).
• The pre-shared key is not set correctly.
Set the same pre-shared key for the camera, and server (see
page 51 of Operating Instructions on the Setup CD-ROM).
• There is a e-mail server or FTP server within the tunnel mode
network.
Transport mode and tunnel mode cannot be used at the
same time. Cancel the e-mail server or FTP server's IPsec
settings, and communicate using tunnel mode.
• Either server's SA or camera's SA is not established.
Restart the camera.
Cause and Remedy