Toshiba TOSVERT VF-AS1 Instruction Manual page 270

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

[23] Pattern operation [3/3]
Communi
Title
cation
Function
No.
Preset speed operation frequency
0570

10 operation mode
Preset speed operation frequency
0571

11 operation mode
Preset speed operation frequency

0572
12 operation mode
Preset speed operation frequency

0573
13 operation mode
Preset speed operation frequency

0574
14 operation mode
Preset speed operation frequency
0575

15 operation mode
[24] Protection functions [1/3]
Communi
Title
cation
Function
No.

0601
Stall prevention level
Inverter trip record retention

0602
selection
0603
Emergency stop

Emergency DC braking control

0604
time
Output phase failure detection

0605
mode selection
0606
OL reduction starting frequency

0607
Motor 150%-overload time limit

Input phase failure detection

0608
mode selection
Low current detection hysteresis

0609
width

0610
Low current trip selection
0611
Low current detection current

0612
Low current detection time

Adjustment range
Ditto
Ditto
Ditto
Ditto
Ditto
Ditto
Adjustment range
0~164%, 165:Deactivated
0:Clear when power is turned off
1:Retain even after power is turned off
0:Coast stop
1:Deceleration stop
2:Emergency DC braking
3:Deceleration stop (deceleration 4)
0.0~20.0 sec.
0:Deselect
1:At starting (only one time after power is turned
on)
2:At starting (each time power is turned on)
3:During operation
4:At starting + during operation
5:Output cut-off detection enabled
0.0~60.0Hz
10~2400 sec.
0:Disabled
1:Enabled
1~20%
0:No trip
1:Trip
0~100%
0~255 sec.
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
1/1
0
Disabled
●/●
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
150
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.1
1.0
Enabled
●/●
1/1
0
Disabled
●/●
0.1/0.01
6.0
Enabled
●/●
1/1
300
Enabled
●/●
1/1
1
Disabled
●/●
1/1
10
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
1/1
0
Enabled
●/●
PM
Torque
V/f Constant Reference
control
control
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
-
5. 12
PM
Torque
V/f Constant Reference
control
control
-
6. 33. 1
●/●
6. 33. 2
●/●
6. 33. 3
●/●
6. 33. 3
●/●
6. 33. 4
●/●
5. 14
●/●
5. 14
●/●
6. 33. 7
●/●
6. 33. 8
●/●
6. 33. 8
●/●
6. 33. 8
●/●
6. 33. 8

Advertisement

Table of Contents
loading

Table of Contents