Toshiba TOSVERT VF-AS1 Instruction Manual page 252

High-performance inverter
Hide thumbs Also See for TOSVERT VF-AS1:
Table of Contents

Advertisement

1. Basic parameter [4/4]
Communi
Title
cation
Function
No.
0007
Factory default setting

Registered parameter
0050

display selection

~
-
Extended parameters


-
Automatic edit function
Adjustment range
0: -
1:50 Hz default setting
2:60 Hz default setting
3:Factory default setting
4:Trip clear
5:Cumulative operation time cleared
6:Initialization of type information
7:Save user-defined parameters
8:Reset of user-defined parameters
9:Cumulative fan operation time record clear
10:Acceleration/deceleration time setting 0.01 sec.~600.0
sec.
11:Acceleration/deceleration time setting 0.1
sec.~6000sec.
0:Standard setting mode at time of activation of motor
1:Quick mode at time of activation of motor
2:Quick mode only
Set detailed parameters shown in the following pages.
-
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Minimum
Vector control
setting unit
Default
Write during
Speed
(Panel/Communi
setting
running
control
cation)
1/1
0
Disabled
●/●
1/1
0
Enabled
●/●
-
-
-
●/●
-
-
●/●
PM
Torque
V/f
Reference
control
control
●/●
5. 20
●/●
5. 22
●/●
-
●/●
4. 2