Selection table of separate-type options (2/2)
Appli
Voltage
-cable
Inverter
class
motor
model
[kW]
0.4
VFAS1-2004PL
0.75
VFAS1-2007PL
1.5
VFAS1-2015PL
2.2
VFAS1-2022PL
3.7
VFAS1-2037PL
5.5
VFAS1-2055PL
7.5
VFAS1-2075PL
11
VFAS1-2110PM
200V
15
VFAS1-2150PM
class
18.5
VFAS1-2185PM
22
VFAS1-2220PM
30
VFAS1-2300PM
37
VFAS1-2370PM
45
VFAS1-2450PM PFL-2200S
55
VFAS1-2550P
75
VFAS1-2750P
0.75
VFAS1-4007PL
1.5
VFAS1-4015PL
2.2
VFAS1-4022PL
3.7
VFAS1-4037PL
5.5
VFAS1-4055PL
7.5
VFAS1-4075PL
11
VFAS1-4110PL
15
VFAS1-4150PL
18.5
VFAS1-4185PL
22
VFAS1-4220PL
30
VFAS1-4300PL
37
VFAS1-4370PL
45
VFAS1-4450PL
55
VFAS1-4550PL
75
VFAS1-4750PL
90
VFAS1-4900PC
110
VFAS1-4110KPC
400V
132
VFAS1-4132KPC
class
160
VFAS1-4160KPC
200
VFAS1-4200KPC
220
VFAS1-4220KPC
280
VFAS1-4280KPC PFL-4800S
355
VFAS1-4355KPC
400
VFAS1-4400KPC
500
VFAS1-4500KPC
(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can be used for the output side in the same manner. For
2
the wire whose size is 22 mm
(*2): Model in square brackets is fitted with top cover.
(*3): To use a 400V/200kW inverter or larger in combination with an external braking resistor (DGP600 series), a braking unit (PB7) with a built-in braking
resistor drive circuit is also needed.
(*4): The options are selected based on the premise that 600V HIV insulated wires (continuous allowable temperature: 75°C) are used.
(*5): Each MSF-****Z model is composed of a reactor, a resistor and a capacitor, and as a guide, use a cable 300m or less in length to connect the inverter
to the motor.
Each MSL-****T model is an output-dedicated surge suppression reactor, and as a guide, use a cable 100m or less in length (or 50m or less for a
shielded cable) to connect the inverter to the motor, although allowable cable lengths vary according to the input voltage.)
(*6): These reactors are usable for each of 200V class and 400V class.
(*7): Be sure to connect DC reactor to 200V-55kW or more or 400V-90kW or more inverter. (Not necessary for DC power input.)
When a 200V-55kW or more inverter or 400V-90 to 280kW inverter is replaced with new one, the reactor (model: DCL-****) used with the current
inverter can be used as-is with the new inverter. In such cases, therefore, you do not need to purchase any reactors in this table.
(*8): To reduce the motor noise, use an inverter with a capacity larger than the motor by one level and set the carrier frequency parameter (CF) at 8kHz or
so.
compliant noise reduction
Input AC
DC reactor
reactor
(DCL)
(ACL)
(*7)
attenuation
PFL-2005S
DCL-2007
PFL-2011S
DCL-2022
Built-in
PFL-2018S
DCL-2037
PFL-2025S
DCL-2055
DCL-2110
PFL-2050S
NF3050A-MJ
NF3080A-MJ
PFL-2100S
Built-in
NF3100A-MJ
PFL-2150S
NF3150A-MJ
NF3200A-MJ
PFL-2300S
DCL1-2550
NF3250A-MJ
NF3200A-MJ
PFL-2400S
DCL1-2750
×2 (parallel)
DCL-2007
(*6)
PFL-4012S
DCL-2022
(*6)
PFL-4025S
DCL-4110
DCL-4220
Built-in
PFL-4050S
PFL-4100S
Built-in
PFL-4150S
DCL1-4900
NF3200C-MJ
PFL-4300S
DCL1-4110K
NF3250C-MJ
DCL1-4132K
PFL-4400S
NF3200C-MJ
DCL1-4160K
×2 (parallel)
DCL1-4200K
PFL-4600S
NF3250C-MJ
×2 (parallel)
DCL1-4280K
NF3250C-MJ
×3(parallel)
PFL-4450S
×2(parallel)
Attached as
VW3A4411
standard
×2(parallel)
PFL-4613S
×2(parallel)
or more, install at least 4 filters in series. Round type (Model: RC5078) is also available.
EMC Diredctive
filter
Braking resistor
(*2)
High
Core
type
type
(*1)
PBR-2007
PBR-2002
PBR-2037
PBR3-2055
PBR3-2075
PBR3-2110
RC9129
PBR3-2150
PBR3-2220
PBR-222W002
DGP600W-B1
[DGP600W-C1]
PBR-2007
PBR-4037
PBR3-4055
PBR3-4075
PBR3-4110
PBR3-4150
PBR3-4220
RC9129
PBR-417W008
DGP600W-B2
[DGP600W-C2]
PB7-4200K(*3)
DGP600W-B3
[DGP600W-C3]
PB7-4200K(*3)
DGP600W-B4
[DGP600W-C4]
PB7-4400K(*3)
FT-1KM
DGP600W-B3
F200160PB
×2(parallel)
[DGP600W-C3
×2(parallel)]
PB7-4400K(*3)
DGP600W-B4
×2(parallel)
[DGP600W-C4
×2(parallel)]
J-7
E6581445
Motor end
Motor
Control
surge voltage
noise
power
suppression
reduction
supply
filter
filter
backup
(*5)
(*8)
NRL-2220
NRL-2300
MSF-4015Z
MSF-4037Z
MSF-4075Z
MSF-4150Z
MSF-4220Z
CPS002Z
MSF-4370Z
(*8)
MSF-4550Z
MSF-4750Z
MSL-4215T
NRL-4230
MSL-4314T
NRL-4300
NRL-4350
MSL-4481T
NRL-4460
NRL-4550
MSL-4759T
-
MSL-41188T
10

Advertisement