Andrew ES45T Installation, Operation And Maintenance Manual page 81

Andrew installation, operation and maintenance 4.5-meter earth station antenna es45t
Table of Contents

Advertisement

Lube
Parts to be Lubricated Action
Point
1
Elevation jackscrew
housing
2
Elevation gear motor
housing fill and drain
3
Azimuth jackscrew
housing
4
Azimuth gear motor
housing fill and drain
5
Panning frame tube
assembly and
thrust pads
Inspection requires checking for visible signs of oil leakage, draining, replacing and
adding oil to ensure appropriate oil level requirements. Excessively dirty oil will require
fresh replacement. If oil leakage is found to be excessive, refer to appropriate trou-
bleshooting information and perform applicable corrective action. Periodic inspection
procedures can be less frequent after first or second scheduled inspections.
Initial oil change requirements include flushing gear boxes with a standard cleaning
agent.
Table 1. Antenna Lubrication Chart
Frequency
Lubricate
Every 3
months
Inspect
Monthly
Change
3 months
Lubricate
3 months
Inspect
Monthly
Change
3 months
Lubricate
3 months
81
Service
Lube
Quantity/
Type
Type
Points
Pressure
SHC32
1
Fitting
Pipe plugs SHC624 10 ounces 47497
Pressure
SHC32
2
Fitting
Pipe plugs SHC624 10 ounces 47497
Aerosol
Dry Moly
Surface
Spray
Lubricant Coverage
Preventive Maintenance
Andrew
Number
49208
49208
207911

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents