2F12-2F21 Codes - Canon iPF9000S Troubleshooting Manual

Ipf5000, ipf700, ipf8000, ipf800, ipf650/750 series
Hide thumbs Also See for iPF9000S:
Table of Contents

Advertisement

Panel display
Code
(last 4
Large LCD
digits)
2F12
LF error
Call for Service.
2F13
Hardware error.
03130031-2F13
Turn off printer,
wait, then
turn on again.
2F14
Hardware error.
03130031-2F14
Turn off printer,
wait, then
turn on again.
2F16
Hardware error.
03130031-2F16
Turn off printer,
wait, then
turn on again.
2F17
Hardware error.
03130031-2F17
Turn off printer,
wait, then
turn on again.
2F1F
Hardware error.
03130031-2F1F
Turn off printer,
wait, then
turn on again.
2F20
Hardware error.
03130031-2F20
Turn off printer,
wait, then
turn on again.
2F21
Rel lever is in
wrong position.
Turn off printer,
wait, then
turn on again.
Small
Small
LCD 1
LCD 2
Power
LF Error
On
Again
Power
Hardware
On
Err 1
Again
031300
31-2F13
Power
Hardware
On
Err 2
Again
Power
Mist Fan
On
Error
Again
Power
Platen
On
Fan
Again
Lock
Power
Platen
On
Fan Err
Again
Power
Purge
On
Motor
Again
Sensor
Error
Power
Motor
On
Cam
Again
Pos
Error
Pinch roller open detected with the pinch
roller locked.
Explanation/Detection sequence
LF error
・An operation order has been received
while the LF suffered a hardware error.
・The target position could not be reached
within a predicted operation time + 3
seconds during an LF operation.
・The sensor could not be detected during an
LF operation involving sensor detection.
A/D converter external trigger output stop
(Hardware error 1)
ASIC register not writable (Hardware error2)
Could not write to the ASIC register on the
main PCB.
Mist fan error
The rotation of the mist fan is not detectable.
Platen fan lock detection error
The lock signal has been supplied
continuously for 3 seconds or longer, 10
seconds after the platen fan started rotating.
Purge sensor error (recovery purge motor
HP detection error)
The recovery system has been driven but no
sensor interrupt occurs.
The recovery system has been driven to
close the cap, but the cap has not been
capped successfully.
Cap motor cam positioning error
The recovery system has been driven but no
sensor interrupt occurs.
The recovery system has been driven to
close the cap, but the cap has not been
capped successfully.
2-43
Chapter 2 Indexes by Case
Remedial Action
(★: Reference fault
isolation procedure
or tool)
①Replace the
LF encoder
sensor.
②Replace the
LF motor.
<Supplement>
・If the carriage
travels heavily
near the stop
position, a
mechanical
load error may
be suspected.
・If any other
symptom is
observed, a
feeding sensor
may be at fault.
Go to ★2F13
(P3-1).
①Replace the
main PCB.
①Check the
bundled wires
in the mist fan
drive circuit.
②Replace the
mist fan unit.
①Check the
bundled wires
in the platen
suction fan
drive circuit.
②Replace the
platen suction
fan unit.
Go to ★
2F1F(P3-2).
Go to ★
2F1F(P3-2).
①Restart with the
pinch roller
closed.
②Check the
sensor in IO
DISPLAY in
Service mode
(Check the
pinch roller
pressure
release
detection SW/
the release lever
lock sensor.)