Fujitsu SPARC Enterprise M4000 Features Manual page 120

Dynamic reconfiguration (dr) user's guide
Hide thumbs Also See for SPARC Enterprise M4000:
Table of Contents

Advertisement

[Remedy] Repeat the action. If this error message appears again, please contact
customer service.
[Output] Console and Standard Output
Error setting up FMEM buffer
[Explanation] DR fails to allocate enough memory to perform copy rename.
[Remedy] Retry and if the problem persists, contact customer service.
Failed to off-line: dr@0:SBX::cpuY
[Explanation] Failed to off-line CPU Y on board X.
[Remedy] Repeat the action. If this error message appears again, please contact
customer service.
[Output] Console and Standard Output
Failed to on-line: dr@0:SBX::cpuY
[Explanation] Failed to online CPU Y on system board X.
[Remedy] Online CPU with psradm -n. If it fails to online CPU, and if this
command fails again, respond in the manner directed by command message.
[Output] Console and Standard Output
Failed to start CPU: dr@0:SBX::cpuY
[Explanation] Failed to start CPU Y on system board X.
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Failed to stop CPU: dr@0:SBX::cpuY
[Explanation] Failed to stop CPU Y on system board X.
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Firmware deprobe failed: SBX::cpuY
[Explanation] Failed to deprobe the CPU.
[Remedy] Please contact customer service.
[Output] Console and Standard Output
Firmware probe failed: SBX
[Explanation] Failed to probe the board.
A-12
SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User's Guide • January 2012