6

INSTALLATION

6.1

Warnings

The use of gas appliances is subject to
statutory control; it is essential to observe
the current regulations and laws in force
(see also chapter 5).
The appliance must discharge combustion
products directly outside or into a suitable ex-
haust duct designed for this purpose.
Combustion products must be discharged
using original flue kits only, since they are inte-
gral parts of the boiler.
For LPG, the appliance must also conform with
the requirements of the distributors and com-
ply with current Regulations and laws in force.
The safety relief valve must be connected to a
suitable drain, or discharge in a safe manner.
The electrical wiring must conform with current
Regulations, in particular:
--- the boiler must be earthed using the cor-
rect bonding clamp.
--- a fused spur isolation switch, with a gap of
at least 3 mm between the contacts must be
installed near to the boiler. Refer to section
6.10 in this chapter for the electrical con-
nections.
In no circumstances will the manufacturer
be held responsible if the warnings and in-
structions contained in this manual have
not been complied with.
6.2

Precautions for installation

For the installation proceed as follows:
--- The boiler must be fixed to a strong wall.
--- The dimensions for the exhaust fume duct de-
tailed in section 6.7 and the correct procedures
for installing the duct, depicted in the instruc-
tion leaflet included with the flue kit, must be
complied with during installation.
--- To allow maintenance procedures it is necess-
ary to leave the minimum gaps indicated in
Fig. 6.1.
200
25
200
Fig. 6.1 (all dimensions in mm)
--- When installing the boiler in a cupboard, cover
or alcove allow at least 50mm permanent clear-
ance from the front face of the boiler. Also en-
sure sufficient clearance to allow free access
for servicing and the lowering of the front con-
trol panel.
--- If the boiler is installed outside, cover the ap-
pliance to protect it against the elements and
add some special anti--- freeze (neutralised) to
the c.h. system.
--- Before installing the boiler on an existing c.h.
system, flush it out thoroughly before fitting the
boiler, so as to remove muddy deposits.
--- It is advisable to equip the system with a sedi-
ment filter, or use a water--- treatment product in
the circulating water.
The latter option in particular, not only cleans
out the system, but also has an anti--- corrosive
effect by promoting formation of a protective
skin on metal surfaces and neutralising gases
present in the water.
We recommend the use of a suitable universal
inhibitory to protect the c.h. system from cor-
rosion.
6.3

Installing the bracket

Precautions
Before mounting the bracket, check that the di-
mensions for fitting the exhaust fume duct are
complied with (refer to the leaflet included with the
flue kit, packed separately).
50