INSTALLATION

5.1 Warnings

Protective gloves must be worn.
The appliance must be installed by
a specialist installer in compliance
with current applicable standards
such as: UNI 7129 2015 part 1-2-3-
4-5 and related standards.
The unit must discharge the com-
bustion products directly outside
or into a suitable exhaust flue de-
signed for that purpose and in
compliance with current national
and local standards.
The unit is not suitable for receiv-
ing condensate from the combus-
tion product evacuation system.
The combustion air must not con-
tain chlorine, ammonia or alkaline
agents.
Installing a boiler near to a swim-
ming pool, washing machine or
laundry room results in an aggres-
sive mixture in the combustion air
around the boiler.
Before installation, it is mandatory to thor-
oughly wash all of the system pipes with
non-aggressive chemical products. The pur-
pose of this procedure is to remove any resi-
dues or impurities that could jeopardise good
boiler operation.
After washing, the system must be treated.
The conventional warranty does not cover any
problems resulting from failure to follow these
instructions.
Check:
• That the boiler is suitable for the type of gas
distributed (check adhesive label).
If it is necessary to convert the boiler to a dif-
- 32 -
INSTALLATION
ferent type of gas, see section "GAS CONVER-
SION" on page 57.
• That the characteristics of the electric, water
and gas supply networks comply with those
on the plate.
The combustion products may only be dis-
charged using the flue gas exhaust kits provid-
ed by the manufacturer, as they are an integral
part of the boiler.
For LPG gas (Propane G31), the installation
must also comply with the requirements of the
distributing companies and with the require-
ments of current technical standards and laws.
The safety valve must be connected to a suit-
able discharge duct to avoid flooding if it is
triggered.
The condensate outlet siphon must be con-
nected to the residential condensate outlet
duct; it must be possible to inspect it and it
must be implemented in such a way as to
avoid the condensate freezing (UNI 7129-5
and related standards).
The electric installation must comply with
technical standards, in particular:
• It is mandatory to connect the boiler to an
effective earthing system via a specific ter-
minal.
• A multiway switch must be installed near
the boiler to allow complete disconnection
in conditions of category III over-voltage. For
the electrical connections, refer to section
"Electrical connections" on page 41.
• The electric conductors for connecting
the remote control to the boiler must go
through different channels than those for
the mains voltage (230 V), as they are sup-
plied with low safety voltage.
If the power supply cable is dam-
aged, it must only be replaced by a
qualified technician.