Maintenance; Warnings; Dismantling The External Panels; Emptying The D.h.w. System - Biasi RIVA COMPACT M90E.24S User Manual And Installation Instructions

Hide thumbs Also See for RIVA COMPACT M90E.24S:
Table of Contents

Advertisement

9

MAINTENANCE

9.1

Warnings

The procedures detailed in this chapter must
be carried out only by a professionally
qualified person. Thus you are advised to
contact an Authorised Service Agent.
For efficient and continuous operation of the
boiler you are advised to have, at least once a
year, maintenance and cleaning done by an
Approved Service engineer.
Isolate the appliance from the electricity
supply by turning off the fused spur isolation
switch adjacent to the appliance and turn off
the gas cock, before carrying out any pro-
cedures, whatsoever, for cleaning, mainten-
ance, opening or dismantling boiler panels.
9.2
Dismantling the external
panels
Front panel
1 Loosen the two screws A (Fig. 9.1).
2 Lift and remove the panel.
Fig. 9.1
34
Side panels
3 Loosen the screws B. Bring the bottom of the
panels away from the boiler and lift them, free-
ing them from the top hooks (Fig. 9.2).
Fig. 9.2
9.3

Emptying the d.h.w. system

1 Turn off the d.c.w. inlet isolating valve (12 in
Fig. 9.3) and turn on the hot water taps and any
drain cocks.
A
15
Fig. 9.3
9.4

Emptying the c.h. system

1 Close the c.h. isolating valves (11 and 15 in
Fig. 9.3).
Closed position
12
13
B
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Riva compact m90e.28sRiva compact m90e.32s

Table of Contents