Technical Data M90E.32S - Biasi RIVA COMPACT M90E.24S User Manual And Installation Instructions

Hide thumbs Also See for RIVA COMPACT M90E.24S:
Table of Contents

Advertisement

Technical information
4.7

Technical data M90E.32S

Nominal heat input
Minimum heat input
Maximum useful output
Minimum useful output
Central heating
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Available head
(in 1000 l/h)
Domestic hot water
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Flow rate
minimum
30° rise
35° rise
40° rise
Injectors
Natural G20
Butane G30
Propane G31
* calculated values subject to tolerance
For the net calorific values of G20, G30, G31 see the technical data at page 12
1 mbar approximately equals 10 mm H
16
kW
35,2
BTU/h
120 102
kW
15,5
BTU/h
52 886
kW
32,0
BTU/h
109 184
kW
12,7
BTU/h
43 435
° C
85
° C
38
kPa
300
bar
3
kPa
30
bar
0,3
kPa
27
bar
0,27
° C
55
° C
35
kPa
1 000
bar
10
kPa
30
bar
0,3
l/min
2,5
l/min
15,3*
l/min
13,1*
l/min
11,5*
130
77
77
O
2
Gas supply pressures
Gas
norm.
Natural
Pa
2 000
G20
mbar
Butane
Pa
2 900
G30
mbar
Propane
Pa
3 700
G31
mbar
Gas pressures at the burner
Gas
Natural
Pa
G20
mbar
Butane
Pa
G30
mbar
Propane
Pa
G31
mbar
Gas rate
Gas
3
Natural
m
/h
G20
Butane
kg/h
G30
Propane
kg/h
G31
Electrical Data
Voltage
Frequency
Power consumption
Protection degree
External fuse rating
Internal fuse rating
min
max
1 700
2 500
20
17
25
2 000
3 500
29
20
35
2 500
4 500
37
25
45
min
max
Ignition
180
1 170
600
1,8
11,7
6,0
500
2 760
1 200
5,0
27,6
12
670
3 570
1 300
6,7
35,7
13
min
max
1,64
3,73
1,22
2,78
1,20
2,73
V~
230
Hz
50
W
180
IPX4D
A
A
1,6 T
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Riva compact m90e.28sRiva compact m90e.32s

Table of Contents