Technical information
4.5
Technical data
mod. M90E.24S
Nominal heat input
Minimum heat input
Maximum useful output
Minimum useful output
Central heating
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Available head
(in 1000 l/h)
Domestic hot water
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Flow rate
minimum
30° rise
35° rise
40° rise
* calculated values subject to tolerance
Net calorific value at 15 ° C and 1013,25 mbar
3
G 20 34,02 MJ/m
G 30 45,6 MJ/kg
G 31 46,4 MJ/kg
1 mbar approximately equals 10 mm H
12
kW
26,6
BTU/h
90 754
kW
11,0
BTU/h
37 530
kW
24,3
BTU/h
82 906
kW
9,1
BTU/h
31 047
° C
85
° C
38
kPa
300
bar
3
kPa
30
bar
0,3
kPa
27
bar
0,27
° C
55
° C
35
kPa
1 000
bar
10
kPa
30
bar
0,3
l/min
2,5
l/min
11,6*
l/min
10,0*
l/min
8,7*
O
2
Injectors
Natural G20
Butane G30
Propane G31
Gas supply pressures
Gas
norm.
Natural
Pa
2 000
G20
mbar
Butane
Pa
2 900
G30
mbar
Propane
Pa
3 700
G31
mbar
Gas pressures at the burner
Gas
Natural
Pa
G20
mbar
Butane
Pa
G30
mbar
Propane
Pa
G31
mbar
Gas rate
Gas
3
Natural
m
/h
G20
Butane
kg/h
G30
Propane
kg/h
G31
130
77
77
min
max
1 700
2 500
20
17
25
2 000
3 500
29
20
35
2 500
4 500
37
25
45
min
max
Ignition
180
1 170
600
1,8
11,7
6,0
500
2 760
1 200
5,0
27,6
12
610
3 570
1 300
6,1
35,7
13
min
max
1,16
2,82
0,87
2,09
0,85
2,06