Installation; Warnings; Precautions For Installation - Biasi RINNOVA ADAPTIVE 30S User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Hide thumbs Also See for RINNOVA ADAPTIVE 30S:
Table of Contents

Advertisement

6

INSTALLATION

6.1

Warnings

The use of gas appliances is
subject to statutory control; it is
essential to observe the current
regulations and laws in force
(see also chapter 5).
The appliance must discharge
combustion products directly
outside or into a suitable ex-
haust duct designed for this
purpose. Combustion products
must be discharged using origi-
nal flue kits only, since they are
integral parts of the boiler.
The appliance is not suitable for
receiving condensate coming
from the combustion products
evacuation system.
Combustion air must avoid con-
tents of chlorine, ammonia, or
alkali agents. Installation of a
boiler near a swimming pool, a
washing machine, or a laundry
does expose combustion air to
these aggressive contents".
Before installing the boiler on an existing
C.H. system, flush it out thoroughly before
fitting the boiler.
This procedure is to remove the presence of
any residues or impurities that could com-
promise good functioning of the boiler.
After flushing it is necessary to treat the sys-
tem.
The conventional warranty does not cover
any problems deriving from failure to com-
ply with such provisions.
For Propane, the appliance must also con-
form with the requirements of the distribu-
tors and comply with current Regulations
and laws in force.
INSTALLATION
The safety relief valve and the condensate
drain must be connected to a suitable drain,
or discharged in a safe manner.
The electrical wiring must conform with cur-
rent Regulations, in particular:
• the boiler must be earthed using the cor-
rect bonding clamp.
• a fused spur isolation switch, must be in-
stalled near to the boiler that allows com-
plete isolation in category III over voltage
conditions.
Refer to section "Electric connection" on
page 41 in this chapter for the electrical
connections.
Under no circumstances will the manu-
facturer be held responsible if the warn-
ings and instructions contained in this
manual have not been complied with.
6.2
• The boiler must be fixed to a strong wall.
• The dimensions for the flue system (de-
tailed in section "Choice of flue" on page
38) and the correct procedures for in-
stalling the flue, depicted in the instruction
leaflet included with the flue kit, must be
complied with during installation.
• To allow maintenance procedures it is
necessary to leave the minimum clear-
ances indicated in Fig. 6.1.

Precautions for installation

The
following
must be respected for installa-
tion:
prescriptions
- 35 -