Electrical Connections - Biasi RIVA COMPACT M90E.24S User Manual And Installation Instructions

Hide thumbs Also See for RIVA COMPACT M90E.24S:
Table of Contents

Advertisement

Installation
The graph in Fig. 6.9 demonstrates the allowable
equivalent lengths for the air supply and flue ex-
haust pipes of model M90E.32S
Flue exhaust "a"
16
15
14
13
12
11
10
9
8
7
6
5
4
3
Restrictor
2
1
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Restrictor
50 mm
Fig. 6.9
Vertical--- roof kit (Fig. 6.10)
This kit allows vertical termination of the flue pipe
through the roof. The kit is 1.2 m in length. Exten-
sion pieces (Co--- axial) are also available which al-
lows the flue system to be extended to a total
overall maximum permissible length.
Optional 45° and 90° elbows can be used to offset
the flue route.
M90E.32S
Allowed values
No
Air intake "b"
See Tab. 6.4 for 24 and 28 kW models)
See Tab. 6.5 for 32 kW model
Fig. 6.10
Vertical flue kit --- condensation
When fitting the 80/125 l flue kits where the equiv-
alent flue length exceeds 3 m a condensate collec-
tor and syphon are required.
If the appliance normally operates at minimum
output power at very low temperatures (e.g. 40 ° C
return / 60 ° C flow), the above equivalent length
should be reduced to 1 m.
The syphon must also be connected to a suitable
drain.
Please, see the boiler accessory leaflet available
from your Supplier for details or contact Biasi UK
Technical Helpline.
6.10

Electrical connections

Connection to the electricity supply
1 Remove the front panel of the case (see the
section 9.2 in this manual).
2 Remove the screws I and J (Fig. 6.11).
3 Loosen the screws K.
Max length
25